Permit: T05CM02674

Parcel: 14026001J

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T05CM02674

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/02/2005 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*OK WALLS & CEILINGS EXCEPT ? ROMEX NOT ALLOWED TO BE RUN BELOW SLAB FOR KITCHEN ISLAND-MUST BE U F
11/30/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245* PUSH IN PLASTIC BUSHIN NOT ALLOWED AT ROMEX TERMINATION INTO METAL BOX UNLESS IT CLAMPS THE CABLE, SEE HALLWAY 2 GANG SWITCH.
CABLE INSTALLED IN OR BELOW SLAB MUST BE UF TYPE, EVEN IFIN PVC PIPE