Permit: T05CM02165
Permit Details
Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
1970 W VALENCIA RD #133
Address NEW:
1970 W VALENCIA RD #133
Apply Date:
05/12/2005
Applicant:
N/A
Description:
FIRE DAMAGE REPAIR FIRE DAMAGE # T05VL00388
Architects:
- 3D ARCHITECTURAL DESIGNS
Contractors:
- CASAS LINDAS DEVELOPMENT CORP ,
Permit Reviews
Permit Number - T05CM02165
Permit Status: Final
Permit Description: FIRE DAMAGE REPAIR FIRE DAMAGE # T05VL00388
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/12/2005 | OTHER | 09/27/2005 | COMPLETED |
| 09/27/2005 | 3RD PARTY REVIEW-COMMERCIAL | 10/05/2005 | COMPLETED |
| 10/06/2005 | POST 3RD PARTY REVIEW | 10/18/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02165
Permit Status: Final
Permit Description: FIRE DAMAGE REPAIR FIRE DAMAGE # T05VL00388
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/12/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM02165
Permit Description: FIRE DAMAGE REPAIR FIRE DAMAGE # T05VL00388
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2005 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection :*FIRE CAULK ALL PENETRATIONS IN FIRE WALLS. |
| 11/08/2005 | ELECTRIC - RECONNECT | DSANTACR | Approved | INSTALL NEW OR REPAIR SMOKE DETECTORS |
| 11/09/2005 | TEP CLEARANCE - AM | JWEATHER | Approved | RECON FOR UNITS #135, 335, 141, 431, 136, 336, 142 AND 342 PER D. SANTACRUZ |
| 11/16/2005 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* 1) UNITS 135, 136, 335, 336, 141, 142, 342 AND 341 ARE INTACT AS ORIGINALLY CONSTRUCTED 2) NOTE: SHOWER DIVERTERS ARE NOT ANTI-SCALD BUT DO MEET CODE STANDARDS APPLICABLE TO ORIGINAL CONSTRUCTION 3) OK FOR TEMP C OF O PER S. LONG |
| 11/16/2005 | FIRE - FINAL | LLAKEY | Approved | APPROVED FOR UNITS 135,136,141,142,335,336,341,&342 ONLY |
| 11/17/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
| 11/22/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | INSULATE ALL SIDEWALL & CEILING REGISTER BOXES ON 2ND FLOOR. PROVIDE FHA PLATE STRAPS UNDER CONDENSATE DRAIN LINES. REMOVE PVC FROM RETURN AIR PLENUMS. CPVC IS OK RECALL FOR INSPECTION |
| 11/23/2005 | BUILDING - PROGRESS | AMATHIES | Approved | IVRS - Inspection :* DO NOT LEAVE PAPER BACKED INSULATION EXPOSED. FRIAME TENNANT SEPARATION WALLS TO BOTTOM OF DECK & ROOF |
| 11/23/2005 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 11/23/2005 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 11/23/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 11/29/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :*NEED TO ISOLATE ALL REFRIG. COPPER FROM STEEL FRAMING, STEEL CLAMPS. |
| 12/01/2005 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* ROOF DRAINS OK WH DRAIN PANS OK ENERGY CONSERVATION REQUIREMENTS TO BE MADE BY THE USE OF HEAT TRAP NIPPLES. RUNNING WATER TEST TO ALL UNDER CONNECTIONS OK. EXCEPT UNIT & 134 RETEST # 134 CALL FOR INSPECTION. PROVIDE TEST ONTUB WASTE & OVER FLOWS ALL UNITS. OK TO COVER ALL WALLS EXCEPT AT REQUIRED TEST LOCATIONS. |
| 12/01/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/01/2005 | PLUMBING - SEWER HCS CONNECT | BBENEDON | Approved | IVRS - Inspection :* |
| 12/01/2005 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* |
| 12/01/2005 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
| 12/02/2005 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* TUB DRAINS, WASTE & OVERFLOW TEST OK RUN TEST FOR CONNECTION TO EXISTING @ # 134 OK CLOSET FLANGES OK |
| 12/13/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/16/2005 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection :*APPROVED |
| 12/28/2005 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
| 12/30/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 12/30/2005 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
| 12/30/2005 | TEP CLEARANCE - PM | JWEATHER | Approved | CLEAR RECN FOR UNITS: #133, 134, 144, 145, 333, 334, 343 AND 344 |
| 01/06/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 01/09/2006 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
| 01/10/2006 | PERMIT FINALED | JWEATHER | Approved |