Inspection History: PLUMBING - PROGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2006 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* | |
| 12/01/2005 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* ROOF DRAINS OK WH DRAIN PANS OK ENERGY CONSERVATION REQUIREMENTS TO BE MADE BY THE USE OF HEAT TRAP NIPPLES. RUNNING WATER TEST TO ALL UNDER CONNECTIONS OK. EXCEPT UNIT & 134 RETEST # 134 CALL FOR INSPECTION. PROVIDE TEST ONTUB WASTE & OVER FLOWS ALL UNITS. OK TO COVER ALL WALLS EXCEPT AT REQUIRED TEST LOCATIONS. |
|
| 11/10/2005 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* UNITS 333,343,344,334,144,134,133,145 PROVIDE MATERIAL SPECS FOR WASTE, VENT, WATER W/STAMP FROM ARCHITERCTURAL TEST ON WATER OK TEST ON WASTE & VENT ABOVE GROUND FLOOR OK REQUIRE TEST ON UNDER SLAB PIPING, INCLUDING CONNECTIONS UNIT 133, LONG RADIOUS 90 REQUIRED FRO TRAP ARM @ LAV COMPLY WITH UPC SEC 605.3 INDIVIDUAL FIXTURE SHUT OFF WIL SATISFY REQUIREMENT KIT.SINK TRAP ARM TO COMPLY WITH SEC. 1003.3 CALL FOR CLOSET FLANGE INSPECTION WHEN READY. CALL FOR ROOF DRAIN INSPECTION WHEN READY. |