Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
04/19/2005
Applicant:
BSW INTERNATIONAL
Description:
TI:JOHNNY ROCKETS

Permit Reviews

Permit Number - T05CM01726
Permit Status: C of o
Permit Description: TI:JOHNNY ROCKETS
Start Date Submittal Complete Date Status  
04/19/2005 PLANS OK TO SUBMIT - COMM 04/19/2005 COMPLETED Review Details
04/19/2005 COMMERCIAL TI 06/20/2005 COMPLETED Review Details
06/20/2005 RESUBMITTAL 08/15/2005 COMPLETED Review Details
08/15/2005 RESUBMITTAL 09/06/2005 COMPLETED Review Details
09/06/2005 RESUBMITTAL 09/08/2005 COMPLETED Review Details
09/08/2005 RESUBMITTAL 09/12/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM01726
Permit Status: C of o
Permit Description: TI:JOHNNY ROCKETS
Total Outstanding Activity Conditions - 1
Date Name
04/19/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM01726
Permit Description: TI:JOHNNY ROCKETS
Total Completed Inspections - 25
Date Description Inspector Results Comments
10/03/2005 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :* N/H DWV WITH HUSKEE BANDS BELOW GRADE OK
WATER TEST TO TEN FEET OK
VENTS TO ABOVE 9 FEET OK
OK TO COVER UNDERGROUND
10/11/2005 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
10/14/2005 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
10/21/2005 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*GAS PRESSURE TEST OK
OK TO COVER OK TO CONNECT TO EXISTING
DO NOT ACTIVATE UNTIL INSPECTOR GIVES OK
11/07/2005 FRAMING AQUIROZ Approved IVRS - Inspection :*
11/15/2005 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
11/15/2005 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
11/18/2005 ENGINEERING - FINAL MRUSSO Approved
11/18/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
11/21/2005 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
11/21/2005 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*CORRECTIONS MADE OK
PLUMBING FINAL OK
OK FOR C OF O PENDING ANY OTHER INSPECTION
11/21/2005 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection :*
11/21/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
11/21/2005 FIRE SPKLR - FINAL LTHOMAS Approved
11/21/2005 MECHANICAL - HOODS CWILLIAM Approved IVRS - Inspection :*
11/21/2005 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection :*
11/22/2005 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection :*
11/22/2005 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection :*
11/23/2005 PERMIT FINALED LJACKSON Approved
11/23/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved
11/23/2005 PLUMBING - ABOVE CEILING RMYERS Approved
11/23/2005 HEALTH DEPT - FINAL 724-7908 JTERRELL Approved
11/23/2005 FIRE - FINAL LLAKEY Approved
11/23/2005 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
11/23/2005 BUILDING - FINAL AQUIROZ Approved

Documents

File Name Document Type  
C OF O_11-23-2005.TIF CERT OF OCC VIEW
ELECTRICREVIEWRESPONSE.TIF DOCUMENTS VIEW
MECHANICALREVIEWRESPONSE.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW