Permit: T05CM01726

Parcel: 10511061R

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM01726

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/21/2005 PLUMBING - FINAL Approved IVRS - Inspection :*CORRECTIONS MADE OK
PLUMBING FINAL OK
OK FOR C OF O PENDING ANY OTHER INSPECTION
11/18/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*WATER HEATER INSTALLED IN INACCESSIBLE LOCATION UNABLE TO SEE THERMOMETER OR CHECK VALVE.
MAY NOT REDUCE OUTLET OF FLOW CONTROL DEVICE
INSTALL ALL STRAINERS AND GRATES
HAND SINK MISSING CLEAN OUT
ALL INDIRECT WASTE GOVERNED BY 94 UPC WILL REQUIRE FULL AIR GAP -MAY NOT BE COMBINED
NO NOTICE FOR ANSUL VALVE
NO RESTRAINTS ON WHEELED GAS APPLIANCE
ALL BACKFLOW DEVICES TO BE TESTABLE.