Permit: T05CM00645
Permit Details
Apply Date:
02/14/2005
Applicant:
K B HOME OF TUCSON *C
Description:
SFR TD#15-44-89
Contractors:
- K B HOME OF TUCSON *C
Outstanding Activity Conditions
Permit Number - T05CM00645
Permit Status: C of o
Permit Description: SFR TD#15-44-89
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/14/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM00645
Permit Description: SFR TD#15-44-89
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/11/2005 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection :* |
| 03/11/2005 | PLUMBING - YARD WTR LINE/TEST | JRIVA | Approved | IVRS - Inspection :* |
| 03/11/2005 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection :* |
| 03/30/2005 | ELECTRIC - UNDERGROUND | JRIVA | Approved | IVRS - Inspection :* |
| 03/30/2005 | ELECTRIC - UFER | JRIVA | Approved | IVRS - Inspection :* |
| 03/30/2005 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection :* |
| 03/30/2005 | STEM WALL/RETAINING WALL | JRIVA | Approved | IVRS - Inspection :* |
| 03/30/2005 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection :* |
| 05/13/2005 | ELECTRIC - TEMPORARY SERVICE | JRIVA | Approved | IVRS - Inspection :* |
| 05/13/2005 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection :* |
| 05/16/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 05/18/2005 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 05/20/2005 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection :* |
| 06/14/2005 | PLUMBING - GAS PRESSURE TEST | JRIVA | Approved | IVRS - Inspection :* |
| 06/15/2005 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection :* |
| 06/15/2005 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection :* |
| 06/15/2005 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection :* |
| 06/16/2005 | U VALUE FOR WINDOW | JRIVA | Approved | IVRS - Inspection :* |
| 06/17/2005 | FRAMING | JRIVA | Approved | IVRS - Inspection :* |
| 06/23/2005 | STUCCO MESH | JRIVA | Approved | IVRS - Inspection :* |
| 06/28/2005 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 08/16/2005 | MECHANICAL - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 08/16/2005 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 08/18/2005 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 08/18/2005 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
| 02/17/2006 | PERMIT FINALED | LJACKSON | Approved |