Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/16/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FINISH LATH ABOVE PORCH 2) FIRE STOP N.W. CORNER 2ND FLOOR 3) OK TO INSULATE |
|
| 06/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE STOP MECH CHASE M/BR S.W. CORNER TOP AND BOTTOM 2) OK TO INSULATE |
|
| 06/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) W/H B-VENT REQUIRES 1" TO COMBUSTIBLES 2) LSL REQUIRES NAILS 4" ON CENTER 3) SOUTH SHEARWALL REQUIRES ANCHOR BOLTS AT 16" ON CENTER 4) WIRES MUST TERMINATE IN APPROVED BOX 5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 6) TOP STAIR RUN LESS THAN 10" 7) BLOCK DEFUSER BOOTS 3 SIDES 8) FIRE STOP MECH CHASE |
|
| 06/13/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JERRY |
|
| 06/12/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 06/09/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY JOE (KBH) |