Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address:
10220 E REES LP
Address NEW:
10220 E REES LP
Apply Date:
12/02/2005
Applicant:
BRUCE R CALL
Description:
CUT 15,900CY FILL 1700CY
Contractors:
  • OKLAND CONSTRUCTION COMPANY INC, TOM HOWELL

Permit Reviews

Permit Number - T05BU02853
Permit Status: Final
Permit Description: CUT 15,900CY FILL 1700CY
Start Date Submittal Complete Date Status  
12/02/2005 PLANS OK TO SUBMIT - GRADING 12/02/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05BU02853
Permit Status: Final
Permit Description: CUT 15,900CY FILL 1700CY
Total Outstanding Activity Conditions - 1
Date Name
12/02/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05BU02853
Permit Description: CUT 15,900CY FILL 1700CY
Total Completed Inspections - 8
Date Description Inspector Results Comments
12/05/2005 ENGINEERING PRE-CONSTRUCTION NKALAHAR Approved MET WITH TOM HOWELL OKLAND CONST 480-296-5393 AND RICK SHERMAN DAR-HIL 909-9130. COVERED POSTING INFORMATION. SILT FENCE IS INSTALLED ALONG NORTH AND WEST PERIMETER ALREADY. DAR-HIL WILL CALL WHEN DRAINAGE STRUCTURE ON SOUTHWEST SIDE OF PROJECT IS FORMED UP-BEFORE POURING CONCRETE.
12/06/2005 STORMWATER INSTALL OF CONTROLS NKALAHAR Approved 18' WADDLE INSTALLED AT THE NW CORNER AT DRAINAGEWAY
SCE IN PLACE ON WEST SIDE OF PROJECT
AZPDES POSTED ALONG NORTH PERIMETER
12/22/2005 GRADING - INTERMEDIATE NKALAHAR Approved SPOKE TO RICK SHERMAN (DAR-HIL) ON SITE. LASER LEVEL WAS SET UP AND SURVEYORS STATE (SHOT) FFE IS 5.85 ABOVE ROAD PRISM. THIS IS CONSISTENT WITH APPROVED PLANS ON SITE/ON FILE
12/28/2005 STORMWATER FOLLOW-UP INSP NKALAHAR Approved DROP OFF FILLED IN AT SW ENTRANCE
ADDL BARRICADES ADDED TO CONSTRUCTION AREA
SWPPP ALL IN GOOD CONDITION
TRICON ON SITE DOING FIRE TIE IN
11/09/2006 STORMWATER FINAL INSPECTION NKALAHAR Approved
11/17/2006 GRADING - FINAL NKALAHAR Approved PER PH CALL
11/17/2006 GRADING - FINAL NKALAHAR Approved OUTSTANDING ISSUES:

-RECEIVED-DRAINAGE/BASIN CERTIFICATION LETTER
-MISSING STRIPING AT ASPHALT PATCH

6/19 -VACTOR TRUCK MUST BE USED ON NEW DRAINAGEWAY BEFORE SEDIMENTS ARE PUSHED INTO C.O.T. STORMDRAIN SYSTEM--RECEIPT OF WORK OR INSPECTOR STANDBY REQUIRED
05/17/2007 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
None IMAGES VIEW
None DOCUMENTS VIEW
None DOCUMENTS VIEW