Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address NEW:
3943 E MONTE VISTA DR
Apply Date:
06/07/2005
Applicant:
IDC
Description:
GRADING
Contractors:
  • LE COCQ CONSTRUCTION COMPANY INC

Permit Reviews

Permit Number - T05BU01446
Permit Status: Expired
Permit Description: GRADING
Start Date Submittal Complete Date Status  
01/17/2006 RESUBMITTAL - GRADING ALL 02/22/2006 COMPLETED Review Details
02/28/2006 RESUBMITTAL - GRADING ALL 04/25/2006 COMPLETED Review Details
06/07/2005 PLANS OK TO SUBMIT - GRADING 06/07/2005 COMPLETED Review Details
06/07/2005 GRADING 07/11/2005 COMPLETED Review Details
09/19/2005 RESUBMITTAL - GRADING ALL 10/25/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05BU01446
Permit Status: Expired
Permit Description: GRADING
Total Outstanding Activity Conditions - 3
Date Name
06/07/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
02/28/2006 LANDSCAPE INSPECTOR MUST CHECK FENCING OF NATURAL AREAS PRIOR TO GRUBBING OR GRADING.
02/28/2006 LANDSCAPE INSPECTION REQUIRED BEFORE FINAL INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05BU01446
Permite Description: GRADING
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
NPPO PRE PERMIT INSPECTION N/A Not Inspected
LANDSCAPE INSPECTION N/A Not Inspected

Completed Inspections

Permit Status: Expired
Permit Number: T05BU01446
Permit Description: GRADING
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/20/2007 GRADING - FINAL JBRUCKME Approved SITE SUPERINTENDENT DAVID STEWART - 235-9077
GRADING PERMIT IS EXPIRED AND MUST BE RE-NEWED.
BUILDING FFE HAS BEEN RAISED APPROXIMATELY 1' ABOVE APPROVED PLAN FFE.
GRADING PLAN IS EXPIRED. IT WAS DESIGNED BY NORMAN AMY, AND REVIEW BY PATRICIA GILBERT FOR THE C.O.T.
THE GRADING PLAN APPEARS TO REQUIRE REVISIONS TO INCLUDE ADDITIONAL INFORMATION.

THE RETENTION/DETENTION BASIN WILL BE DEEPER THAN 2' AND WILL REQUIRE BARRICADE RAILING AND MORE ROCK RIPRAP FOR STEEP SLOPES,

SITE RECEIVES OFF-SITE RUN-ON Q100 7.3 CFS AND DISCHARGES Q100 7.0 CFS. THERE IS OUTFALL OR WALL OPENING PROVISIONS OR DETAILS FOR THE DISCHARGE FROM THE R/D BASIN.

A 2' BENCH AT EXISTING GRADE IS REQUIRED AT THE INSIDE PERIMETER OF THIS SITE. THE GRADING PLAN SHOULD SHOW THIS BENCH AS WELL AS THE SLOPES AND DEPTH OF THE SWALE.
11/13/2007 GRADING - CHECK FOR ACTIVITY JBRUCKME Approved I MET WITH DAVID AND MARS (OWNER) TO REVIEW THE AS-BUILT GRADING PLANS PRIOR TO APPROVAL BY JIM VOGELSBURG.

THE EAST PERIMETER EXISTING WALL DRAINAGE OPENINGS ARE BLOCKED WITH SOIL. THE PLAN DOES NOT SHOW THESE EXISTING OPENINGS. THE PLAN SHOULD SHOW ALL EXISTING OPENINGS ON THE EAST AND NORTH PERIMETERS.

THE EXISTING FENCE ON THE WEST PERIMETER IS BEING USED FOR RETAINING. SOIL NEEDS TO BE PULLED BACK AWAY FROM FENCE.

PROVIDE ROCK RIP RAP AT DRAINAGE CONCENTRATION POINTS AND WHERE SOIL NEEDS TO BE HELD BACK AWAY FROM FENCING.