Permit: T05BU01446
Permit Details
Status:
Expired
Type:
COMMERCIAL OTHER
Address:
3943 E MONTE VISTA DR
Address NEW:
3943 E MONTE VISTA DR
Apply Date:
06/07/2005
Applicant:
IDC
Description:
GRADING
Contractors:
- LE COCQ CONSTRUCTION COMPANY INC
Permit Reviews
Permit Number - T05BU01446
Permit Status: Expired
Permit Description: GRADING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/17/2006 | RESUBMITTAL - GRADING ALL | 02/22/2006 | COMPLETED |
| 02/28/2006 | RESUBMITTAL - GRADING ALL | 04/25/2006 | COMPLETED |
| 06/07/2005 | PLANS OK TO SUBMIT - GRADING | 06/07/2005 | COMPLETED |
| 06/07/2005 | GRADING | 07/11/2005 | COMPLETED |
| 09/19/2005 | RESUBMITTAL - GRADING ALL | 10/25/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05BU01446
Permit Status: Expired
Permit Description: GRADING
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 06/07/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 02/28/2006 | LANDSCAPE INSPECTOR MUST CHECK FENCING OF NATURAL AREAS PRIOR TO GRUBBING OR GRADING. |
| 02/28/2006 | LANDSCAPE INSPECTION REQUIRED BEFORE FINAL INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05BU01446
Permite Description: GRADING
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| NPPO PRE PERMIT INSPECTION | N/A | Not Inspected | ||
| LANDSCAPE INSPECTION | N/A | Not Inspected |
Completed Inspections
Permit Status: Expired
Permit Number: T05BU01446
Permit Description: GRADING
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2007 | GRADING - FINAL | JBRUCKME | Approved | SITE SUPERINTENDENT DAVID STEWART - 235-9077 GRADING PERMIT IS EXPIRED AND MUST BE RE-NEWED. BUILDING FFE HAS BEEN RAISED APPROXIMATELY 1' ABOVE APPROVED PLAN FFE. GRADING PLAN IS EXPIRED. IT WAS DESIGNED BY NORMAN AMY, AND REVIEW BY PATRICIA GILBERT FOR THE C.O.T. THE GRADING PLAN APPEARS TO REQUIRE REVISIONS TO INCLUDE ADDITIONAL INFORMATION. THE RETENTION/DETENTION BASIN WILL BE DEEPER THAN 2' AND WILL REQUIRE BARRICADE RAILING AND MORE ROCK RIPRAP FOR STEEP SLOPES, SITE RECEIVES OFF-SITE RUN-ON Q100 7.3 CFS AND DISCHARGES Q100 7.0 CFS. THERE IS OUTFALL OR WALL OPENING PROVISIONS OR DETAILS FOR THE DISCHARGE FROM THE R/D BASIN. A 2' BENCH AT EXISTING GRADE IS REQUIRED AT THE INSIDE PERIMETER OF THIS SITE. THE GRADING PLAN SHOULD SHOW THIS BENCH AS WELL AS THE SLOPES AND DEPTH OF THE SWALE. |
| 11/13/2007 | GRADING - CHECK FOR ACTIVITY | JBRUCKME | Approved | I MET WITH DAVID AND MARS (OWNER) TO REVIEW THE AS-BUILT GRADING PLANS PRIOR TO APPROVAL BY JIM VOGELSBURG. THE EAST PERIMETER EXISTING WALL DRAINAGE OPENINGS ARE BLOCKED WITH SOIL. THE PLAN DOES NOT SHOW THESE EXISTING OPENINGS. THE PLAN SHOULD SHOW ALL EXISTING OPENINGS ON THE EAST AND NORTH PERIMETERS. THE EXISTING FENCE ON THE WEST PERIMETER IS BEING USED FOR RETAINING. SOIL NEEDS TO BE PULLED BACK AWAY FROM FENCE. PROVIDE ROCK RIP RAP AT DRAINAGE CONCENTRATION POINTS AND WHERE SOIL NEEDS TO BE HELD BACK AWAY FROM FENCING. |