Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2005 BLANCA ESPINO ENGINEERING REVIEW Denied Grading Plan
1. Indicate a dimensioned detail of weep holes. Indicate water surface elevation. Indicate and label all weep holes throughout wall.

2. Indicate water surface elevation and drainage slopes for drainage swales.

3. Indicate contour intervals along with north arrow and scale.

4. The refuse container location indicates ponding. Correct for proper drainage.

5. Indicate finished floor elevations for structures as per the drainage statement. Indicate datum used to determine finish floor elevation.

6. Indicate a dimensioned detail of PAAL from property line to property line.

Drainage Statement
1. Indicate parcel code number 110-06-0760 to Sheet 1 Paragraph 1.

2. Indicate maintenance responsible party; name, address, and telephone number of the person (s) responsible for operation, maintenance and liability for any or all drainage structures and weep holes.

3. Add a statement on the type of impact the discharge from the water harvesting will have to the adjacent properties.
06/23/2005 ANDREW CONNOR NPPO REVIEW Denied Site plan approval is necessary to continue review.
06/27/2005 DAN CASTRO ZONING REVIEW Denied Grading plan may not be approved by the Zoning Review Section prior to site plan approval and Engineering Section approval of the grading plan.