Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T04EL00215
Permit Details
Apply Date:
02/03/2004
Applicant:
AMBASSADOR ELECTRIC SERVICE,*T
Description:
2 HR ELEC INSP FOR GEM SHOW APA
Contractors:
- AMBASSADOR ELECTRIC SERVICE,*T
Outstanding Activity Conditions
Permit Number - T04EL00215
Permit Status: Expired
Permit Description: 2 HR ELEC INSP FOR GEM SHOW APA
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/03/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04EL00215
Permite Description: 2 HR ELEC INSP FOR GEM SHOW APA
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/04/2004 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection 0000*/ AT PATIO AREA: 1) EXTENSION CORD CONNECTOR TO BE RAISED TO PREVENT SUBMISSION WHEN WET 2) NEED GFCI PROTECTION AT SOURCE, NEED RAIN TIGHT RECEPTACLE COVER (WHEN IN USE)-ALL AREAS 3) REFRIGERATION-CASE WILL NEED IT'S OWN SINGLE RECEPTACLE AND A WATER SHIELD AT TOP (OPEN WIRING) |