Permit Details

Status:
C of o
Type:
COMMERCIAL OTHER
Apply Date:
12/01/2004
Applicant:
METRO PERMIT EXPRESS, INC
Description:
RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
Architects:
  • LANCE, GEORGE GERARD
Contractors:
  • YARBOROUGH DEVELOPMENT INC

Permit Reviews

Permit Number - T04CM05222
Permit Status: C of o
Permit Description: RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
Start Date Submittal Complete Date Status  
02/14/2005 POST 3RD PARTY REVIEW 02/18/2005 COMPLETED Review Details
02/18/2005 RESUBMITTAL 03/01/2005 COMPLETED Review Details
04/14/2005 3RD PARTY REVIEW-REVISION/OTHER 04/20/2005 COMPLETED Review Details
12/01/2004 PLANS OK TO SUBMIT - 3RD PARTY 12/03/2004 COMPLETED Review Details
12/03/2004 3RD PARTY REVIEW-COMMERCIAL TI 02/14/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM05222
Permit Status: C of o
Permit Description: RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
Total Outstanding Activity Conditions - 1
Date Name
12/01/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM05222
Permit Description: RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
Total Completed Inspections - 38
Date Description Inspector Results Comments
03/07/2005 PLUMBING - ROUGH, SOIL RMYERS Approved 1) 3925 & 3927 N FLOWING WELLS HAVE THE SAME PERMIT NUMBER-ONLY ONE COPY WILL CONTAIN NOTES. 2) ABS DWV UNDER SLAB NOT INSTALLED PER PLAN. REDLINES ON SITE. OK TO COVER SUBJ. TO REVISED PLAN. WATER TEST ONE RISER TO TEN FEET.
04/06/2005 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
04/08/2005 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :* 1) PRESSURE TEST OK OK TO COVER
04/08/2005 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
04/14/2005 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1) CONTRACTOR TO RED LINE WATER ROUTING CHANGE
2) OK TO COVER SUBJECT TO REVISED APPROVED PLAN
3) ABS DWV THRU ROOF-OK
4) COPPER RED LINES-OK
5) FLANGES-OK
6) OK TO COVER ALL AREAS
04/14/2005 ELECTRIC - TEMP POWER FOR TEST MCAPISTR Approved IVRS - Inspection :* T/S FOR TEST OK BOND NOT REQUIRED. THIS IS XSTNG. ELECTRIC SERVICE. & SES
04/14/2005 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection :*
04/20/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :* SUSPENDED ROUGH DUCT
04/25/2005 FRAMING AMATHIES Approved IVRS - Inspection :*
04/25/2005 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection :*
04/29/2005 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :* 1) HANGER CORRECTIONS MADE OK 2) OK TO COVER
05/13/2005 ELECTRIC - TEMPORARY SERVICE MCAPISTR Approved IVRS - Inspection :*LAY IN LITE FIXTURES MUST BE MECHANICALLY FASTENED TO CEILING T -GRID. THEY MAY BE SCREWED IN WITH ONE SCREW AT CENTER OF FIXTURE AT EACH END. YOU MAY ALSO USE FACTORY MADE CLIPS. 2) FIXTURE CONNECTING MC CABLES / WHIPS LONGER THAN 6" FEET MUST SUPPORT FROM WIRES INSTALLED FOR THE PURPOSE. DO NOT USE GRID SUPPORT WIRES TO SUPPORT CABLES. RECALL WHEN COMPLETED. DO NOT TILE.
05/15/2005 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
05/15/2005 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
05/15/2005 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
05/16/2005 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*1) OK TO COVER ALL AREAS
05/16/2005 TEP CLEARANCE - AM JKOZUCH Approved ECO AGAIN
05/25/2005 ELECTRIC - ABOVE CEILING MCAPISTR Approved IVRS - Inspection :*
06/02/2005 FIRE SPKLR - FINAL LTHOMAS Approved
06/14/2005 MECHANICAL - ABOVE CEILING CWILLIAM Approved
06/14/2005 PLUMBING - FINAL RMYERS Approved 1. NO SEWER POC TO EXISTING 2. YARDWATER NOT REQUIRED P.O.C TO EXISTING IN SHELL. 3. OK FOR TEMP POWER STOI. 4. GAS TO ROOF TOP UNITS OK 5) PLUMBING FINAL OK. OK FOR C OF O PENDING ANY OTHER INSPECTION.
06/14/2005 ELECTRIC - FINAL MCAPISTR Approved
06/14/2005 ELECTRIC - RECONNECT MCAPISTR Approved IVRS - Inspection :*
06/14/2005 ELECTRIC - SERVICE UPGRADE MCAPISTR Approved IVRS - Inspection :*
06/14/2005 ELECTRIC - CONSTRUCTION POWER MCAPISTR Approved IVRS - Inspection :*
06/14/2005 PLUMBING - GAS RECONNECT RMYERS Approved IVRS - Inspection :*
06/14/2005 PLUMBING - TEMP POWER FOR TEST RMYERS Approved IVRS - Inspection :*
06/14/2005 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
06/14/2005 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
06/14/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
06/14/2005 SIGN - FINAL RDEAR Approved IVRS - Inspection :*
06/15/2005 BUILDING - TEMP POWER FOR TEST AQUIROZ Approved IVRS - Inspection :*
06/15/2005 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
06/28/2005 OUTDOOR LIGHTING FINAL MCAPISTR Approved IVRS - Inspection :*
06/28/2005 FIRE - FINAL LTHOMAS Approved
06/29/2005 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :* DOOR LOCKED/NO ACCESS.
06/29/2005 BUILDING - FINAL BSTEVENS Approved IVRS - Inspection :
There is no access to the site.| 920*
06/30/2005 PERMIT FINALED JMORALES Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_06-15-2009.TIF CERT OF OCC VIEW
C OF O_06-30-2005.TIF CERT OF OCC VIEW