Permit: T04CM05222
Permit Details
Status:
C of o
Type:
COMMERCIAL OTHER
Address:
3925 N FLOWING WELLS RD
Address NEW:
3925 N FLOWING WELLS RD
Apply Date:
12/01/2004
Applicant:
METRO PERMIT EXPRESS, INC
Description:
RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
Architects:
- LANCE, GEORGE GERARD
Contractors:
- YARBOROUGH DEVELOPMENT INC
Permit Reviews
Permit Number - T04CM05222
Permit Status: C of o
Permit Description: RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/14/2005 | POST 3RD PARTY REVIEW | 02/18/2005 | COMPLETED |
| 02/18/2005 | RESUBMITTAL | 03/01/2005 | COMPLETED |
| 04/14/2005 | 3RD PARTY REVIEW-REVISION/OTHER | 04/20/2005 | COMPLETED |
| 12/01/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 12/03/2004 | COMPLETED |
| 12/03/2004 | 3RD PARTY REVIEW-COMMERCIAL TI | 02/14/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM05222
Permit Status: C of o
Permit Description: RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/01/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM05222
Permit Description: RENOVATION:ROOF TRUSS/PLUMBING/MECHANICAL/ELECTRICAL:BLDG A FOR RETAIL
Total Completed Inspections - 38
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | 1) 3925 & 3927 N FLOWING WELLS HAVE THE SAME PERMIT NUMBER-ONLY ONE COPY WILL CONTAIN NOTES. 2) ABS DWV UNDER SLAB NOT INSTALLED PER PLAN. REDLINES ON SITE. OK TO COVER SUBJ. TO REVISED PLAN. WATER TEST ONE RISER TO TEN FEET. |
| 04/06/2005 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/08/2005 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* 1) PRESSURE TEST OK OK TO COVER |
| 04/08/2005 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
| 04/14/2005 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1) CONTRACTOR TO RED LINE WATER ROUTING CHANGE 2) OK TO COVER SUBJECT TO REVISED APPROVED PLAN 3) ABS DWV THRU ROOF-OK 4) COPPER RED LINES-OK 5) FLANGES-OK 6) OK TO COVER ALL AREAS |
| 04/14/2005 | ELECTRIC - TEMP POWER FOR TEST | MCAPISTR | Approved | IVRS - Inspection :* T/S FOR TEST OK BOND NOT REQUIRED. THIS IS XSTNG. ELECTRIC SERVICE. & SES |
| 04/14/2005 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection :* |
| 04/20/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* SUSPENDED ROUGH DUCT |
| 04/25/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 04/25/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
| 04/29/2005 | PLUMBING - ROOF DRAINS | RMYERS | Approved | IVRS - Inspection :* 1) HANGER CORRECTIONS MADE OK 2) OK TO COVER |
| 05/13/2005 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection :*LAY IN LITE FIXTURES MUST BE MECHANICALLY FASTENED TO CEILING T -GRID. THEY MAY BE SCREWED IN WITH ONE SCREW AT CENTER OF FIXTURE AT EACH END. YOU MAY ALSO USE FACTORY MADE CLIPS. 2) FIXTURE CONNECTING MC CABLES / WHIPS LONGER THAN 6" FEET MUST SUPPORT FROM WIRES INSTALLED FOR THE PURPOSE. DO NOT USE GRID SUPPORT WIRES TO SUPPORT CABLES. RECALL WHEN COMPLETED. DO NOT TILE. |
| 05/15/2005 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/15/2005 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/15/2005 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/16/2005 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :*1) OK TO COVER ALL AREAS |
| 05/16/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO AGAIN |
| 05/25/2005 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection :* |
| 06/02/2005 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 06/14/2005 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 06/14/2005 | PLUMBING - FINAL | RMYERS | Approved | 1. NO SEWER POC TO EXISTING 2. YARDWATER NOT REQUIRED P.O.C TO EXISTING IN SHELL. 3. OK FOR TEMP POWER STOI. 4. GAS TO ROOF TOP UNITS OK 5) PLUMBING FINAL OK. OK FOR C OF O PENDING ANY OTHER INSPECTION. |
| 06/14/2005 | ELECTRIC - FINAL | MCAPISTR | Approved | |
| 06/14/2005 | ELECTRIC - RECONNECT | MCAPISTR | Approved | IVRS - Inspection :* |
| 06/14/2005 | ELECTRIC - SERVICE UPGRADE | MCAPISTR | Approved | IVRS - Inspection :* |
| 06/14/2005 | ELECTRIC - CONSTRUCTION POWER | MCAPISTR | Approved | IVRS - Inspection :* |
| 06/14/2005 | PLUMBING - GAS RECONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 06/14/2005 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection :* |
| 06/14/2005 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 06/14/2005 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 06/14/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 06/14/2005 | SIGN - FINAL | RDEAR | Approved | IVRS - Inspection :* |
| 06/15/2005 | BUILDING - TEMP POWER FOR TEST | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/15/2005 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/28/2005 | OUTDOOR LIGHTING FINAL | MCAPISTR | Approved | IVRS - Inspection :* |
| 06/28/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 06/29/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* DOOR LOCKED/NO ACCESS. |
| 06/29/2005 | BUILDING - FINAL | BSTEVENS | Approved | IVRS - Inspection : There is no access to the site.| 920* |
| 06/30/2005 | PERMIT FINALED | JMORALES | Approved |