Description:
TI:FRATERNITY KITCHEN
Architects:
  • FLOREZ, JESUS L.
Contractors:
  • AZ BUILDERS AND MAINTENANCE COMPANY INC

Permit Reviews

Permit Number - T04CM04075
Permit Status: Final
Permit Description: TI:FRATERNITY KITCHEN
Start Date Submittal Complete Date Status  
04/27/2005 REVISION 04/28/2005 COMPLETED Review Details
06/30/2005 REVISION 07/14/2005 COMPLETED Review Details
07/29/2005 REVISION 07/29/2005 COMPLETED Review Details
09/09/2004 COMMERCIAL TI 09/16/2004 COMPLETED Review Details
10/15/2004 REVISION 10/22/2004 COMPLETED Review Details
10/22/2004 RESUBMITTAL 10/29/2004 COMPLETED Review Details
11/19/2004 RESUBMITTAL 12/03/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM04075
Permit Status: Final
Permit Description: TI:FRATERNITY KITCHEN
Total Outstanding Activity Conditions - 1
Date Name
09/09/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM04075
Permit Description: TI:FRATERNITY KITCHEN
Total Completed Inspections - 14
Date Description Inspector Results Comments
09/17/2004 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*/SUPPORT M/C WITHIN 12" O F BOX2)SUPPORT PVC CONDUIT AS IT ENTERS WALL 3)TIGHTEN LOOSE FITTINGS (ALL) 4)SUPPORT BOXES 5)PLEASE REVISE PLANS FOR CAN FIXTURES 6)PLEASE ADD 02035,02010,02036 TO PERMIT 7)SUPPORT CONDUITS AS PER CODES 8)INSTALL GROUND SCREWS 3/4 OF A TURN WITH CONDOUTOR
09/20/2004 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*/1)I WILL REQUIRE A DWV ISOMETRIC FOR REPIPE IN KITCHEN. IT APPEARS THAT THERE IS A MIXED COMBINATION WASTE AND VENT, AND CONVENTIONAL PIPING SYSTEM 2)DBL FIXTURE FITTING MAY NOT BE INSTALLED IN THE HORIZONTAL POSITION 3)GAS UNDER SLAB TO BE SLEEVED IN APPROVED MANNER 4)TEMPORARY DRAINS MUST MAINTAIN AIR GAP 5)WILL REQUIRE AN APPROVED KITCHEN EQUIPMENT PLAN
08/15/2005 SHEET ROCK NAILING HLEYVA Approved
09/01/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved
09/01/2005 MECHANICAL - ABOVE CEILING CWILLIAM Approved
09/01/2005 MECHANICAL - HOODS CWILLIAM Approved
09/01/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
09/07/2005 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) OK TO COVER ALL AREAS
3) GAS OK
09/07/2005 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
09/07/2005 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
09/07/2005 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
09/08/2005 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1) CORRECTION MADE OK
2) OK FOR C OF O PENDING ANY OTHER INSPECTIONS
09/09/2005 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :*
09/12/2005 PERMIT FINALED CFRAKER Approved