Permit: T04CM04075

Parcel: 12317252B


Addresses:

1510 N VINE AV


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM04075

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/04/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* 1) OK FOR CONCRETE STOI
04/29/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :* 1) APPROVED PLAN ON SITE. 2) PVC DWV SS INTALLED OK TO P.O.C W/EXISTING IN BASEMENT. 3) CONTRACTOR TO ELIMINATE GAS IN BASEMENT ( NO GAS IN OR ON THE GROUND UNDER ANY BUILDING) 4) GREASE WASTE, TRAP W/VENT, AND RECONNECT TO SS OK. 5) OK TO COVER
04/15/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :* 1) VENT AT GREASE TRAP NOT INSTALLED PER PLAN. REMEMBER-PVC REQUIRES AT LEAST 12" OF COVER AND IS NOT PERMITTED IN EXPOSED EXTERIOR LOCATIONS. 2) FLOW CONTROL IS INSTALLED AT THE TAILPIECE OF EACH FIXTURE DRAINING TO TRAP. 3) PLUMBING NOT INSTALLED PER PLAN. PLUMBING THAT IS SHOWN AS EXISITING ON THE PLAN, ISN'T. REVISE PLAN TO REFLECT INSTALLATION. 4) UNABLE TO SEE WHERE GAS EXITS THE BUILDING
09/20/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/1)I WILL REQUIRE A DWV ISOMETRIC FOR REPIPE IN KITCHEN. IT APPEARS THAT THERE IS A MIXED COMBINATION WASTE AND VENT, AND CONVENTIONAL PIPING SYSTEM 2)DBL FIXTURE FITTING MAY NOT BE INSTALLED IN THE HORIZONTAL POSITION 3)GAS UNDER SLAB TO BE SLEEVED IN APPROVED MANNER 4)TEMPORARY DRAINS MUST MAINTAIN AIR GAP 5)WILL REQUIRE AN APPROVED KITCHEN EQUIPMENT PLAN