Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM04075
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) OK FOR CONCRETE STOI | |
| 04/29/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) APPROVED PLAN ON SITE. 2) PVC DWV SS INTALLED OK TO P.O.C W/EXISTING IN BASEMENT. 3) CONTRACTOR TO ELIMINATE GAS IN BASEMENT ( NO GAS IN OR ON THE GROUND UNDER ANY BUILDING) 4) GREASE WASTE, TRAP W/VENT, AND RECONNECT TO SS OK. 5) OK TO COVER | |
| 04/15/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) VENT AT GREASE TRAP NOT INSTALLED PER PLAN. REMEMBER-PVC REQUIRES AT LEAST 12" OF COVER AND IS NOT PERMITTED IN EXPOSED EXTERIOR LOCATIONS. 2) FLOW CONTROL IS INSTALLED AT THE TAILPIECE OF EACH FIXTURE DRAINING TO TRAP. 3) PLUMBING NOT INSTALLED PER PLAN. PLUMBING THAT IS SHOWN AS EXISITING ON THE PLAN, ISN'T. REVISE PLAN TO REFLECT INSTALLATION. 4) UNABLE TO SEE WHERE GAS EXITS THE BUILDING | |
| 09/20/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :*/1)I WILL REQUIRE A DWV ISOMETRIC FOR REPIPE IN KITCHEN. IT APPEARS THAT THERE IS A MIXED COMBINATION WASTE AND VENT, AND CONVENTIONAL PIPING SYSTEM 2)DBL FIXTURE FITTING MAY NOT BE INSTALLED IN THE HORIZONTAL POSITION 3)GAS UNDER SLAB TO BE SLEEVED IN APPROVED MANNER 4)TEMPORARY DRAINS MUST MAINTAIN AIR GAP 5)WILL REQUIRE AN APPROVED KITCHEN EQUIPMENT PLAN |