Permit: T04CM04013
Permit Details
Status:
Expired
Type:
COMMERCIAL ADDITION
Address:
5561 E SPEEDWAY BL
Address NEW:
5561 E SPEEDWAY BL
Apply Date:
09/02/2004
Applicant:
DAVID E SHAMBUCH
Description:
ADDITION:3 SERVICE BAYS
Contractors:
- ODEN CONSTRUCTION INC
Permit Reviews
Permit Number - T04CM04013
Permit Status: Expired
Permit Description: ADDITION:3 SERVICE BAYS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/02/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 09/02/2004 | COMPLETED |
| 09/02/2004 | 3RD PARTY REVIEW-COMMERCIAL | 09/24/2004 | COMPLETED |
| 09/24/2004 | POST 3RD PARTY REVIEW | 09/30/2004 | COMPLETED |
| 10/01/2004 | RESUBMITTAL | 10/07/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM04013
Permit Status: Expired
Permit Description: ADDITION:3 SERVICE BAYS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/02/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04CM04013
Permite Description: ADDITION:3 SERVICE BAYS
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| RIGHT OF WAY - FINAL | N/A | Not Inspected | ||
| 06/01/2005 | BUILDING - FINAL | N/A | Partial Approval | OPENED BY S LONG. FINAL WAS GIVEN WITHOUT C OF O INSPECTIONS APPROVALS |
| 06/07/2005 | ENGINEERING - FINAL | N/A | Denied | NO SITE WORK HAS BEEN COMPLETED. 1. COMPLETE ALL SITE WORK AS SHOWN ON THE SITE PLAN PAGE C1. 2. PROVIDE ALL PAVEMENT STRIPING, CONCRETE WHEEL STOPS, HANDICAP PARKING WITH SIGN AND PEDESTRIAN WALKWAYS. 3. PROVIDE ALL PERIMETER IMPROVEMENTS INCLUDING CURBS, CURB RETURNS, LANDCAPING PLANTERS/BUFFERS, SCREEN WALLS AND SIDEWALK SCUPPER. 4. PROVIDE REFUSE CAN ENCLOSURE WITH 6' SCREEN WALL. 5. PROVIDE A NEW HANDICAP ACCESS RAMP PER ADA REQUIREMENTS AT SOUTHEAST CORNER OF BUILDING.. 6. PROVIDE HANDICAP RAMPS AT NEW CURB RETURNS ON SPEEDWAY. 7. PROVIDE APPROVED WASTE OIL AND ANTIFREEZE STORAGE THAT PREVENTS CONTACT WITH STORMWATER AND HAS SECONDARY SPILL CONTAINMENT. 8. CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS. 9. REMOVE ROLL-OFF CONTAINER BLOCKING GARAGE ACCESS. |
| 06/08/2005 | LANDSCAPE - FINAL | N/A | Denied | Complete all site and landscape per plan. |
Completed Inspections
Permit Status: Expired
Permit Number: T04CM04013
Permit Description: ADDITION:3 SERVICE BAYS
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2005 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection :* OK TO 8' AFF |
| 03/14/2005 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection :* |
| 03/22/2005 | REINFORCED MASONRY PRE-GROUT | BSTEVENS | Approved | IVRS - Inspection :* APPROVED |
| 04/15/2005 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 04/20/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
| 04/28/2005 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection :* IF FIXTURES ABOVE 12"- THEY WILL NOT BE IN CLASSIFIED AREA-NO LETTER REQUIRED. |
| 04/28/2005 | TEP CLEARANCE - PM | JKOZUCH | Approved | CEC AND RELOCATION PER R MAJUTA CALLED IN AT 11:10AM |
| 05/06/2005 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection :* |
| 05/26/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR C OF O |
| 05/26/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 05/26/2005 | FIRE - FINAL | CSCHULTZ | Approved | |
| 05/31/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* 1) OVERHEAD WATER DISTRIBUTION IS OK 2) FINAL CONNECTIONS TO NEW COOLERS ARE OK |
| 05/31/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* |
| 05/31/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* |
| 06/01/2005 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* OK FINAL RECEIVED LETTER FOR AREA USAGE. |
| 06/01/2005 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 06/01/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 06/01/2005 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* |
| 06/01/2005 | STEM WALL/RETAINING WALL | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/07/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :*NO SIGNS TO BE PLACED ON LIGHT POLES |