Permit: T04CM03709
Permit Details
Apply Date:
08/11/2004
Applicant:
DIANA HOLLINGSWORTH MICHAELS & JEFFREY MICHAELS
Description:
REMODEL:SFR
Outstanding Activity Conditions
Permit Number - T04CM03709
Permit Status: C of o
Permit Description: REMODEL:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/11/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM03709
Permit Description: REMODEL:SFR
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/05/2004 | PLUMBING - ROUGH, SOIL | ROHAVER | Approved | IVRS - Inspection :* |
| 10/28/2004 | EXCAVATION/LAYOUT REBAR & ZON | ROHAVER | Approved | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CORRECTIONS NOT MADE 2) ENGINEER OF RECORD WILL GET SPECIAL INSPECTION PAPERWORK SUBMITTAL TO PLAN CHECK AND BACK ON JOB SITE FOR VERIFICATIONS OF 01005, 01015 SPECIAL INSPECTION APPROVAL BY CERTIFIED SPECIAL INSPECTOR |
| 10/28/2004 | BUILDING PRE-SLAB | ROHAVER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/12/2005 | ELECTRIC - CONSTRUCTION POWER | ROHAVER | Approved | IVRS - Inspection :* |
| 08/15/2005 | TEP CLEARANCE - AM | FGREER | Approved | ECO CLEARED BY OHAVER |
| 08/16/2005 | ROOF NAILING | ROHAVER | Approved | IVRS - Inspection :* |
| 08/16/2005 | EXT METAL CLIPS/EXT SHEATHING | ROHAVER | Approved | IVRS - Inspection :* |
| 09/30/2005 | PLUMBING - GAS PRESSURE TEST | HPEDROZA | Approved | IVRS - Inspection :* |
| 09/30/2005 | MECHANICAL - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection :* |
| 09/30/2005 | PLUMBING - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection :* |
| 09/30/2005 | ELECTRIC - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection :* |
| 09/30/2005 | FRAMING | HPEDROZA | Approved | IVRS - Inspection :* |
| 10/05/2005 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection :* |
| 10/14/2005 | SHEET ROCK NAILING | ROHAVER | Approved | IVRS - Inspection :* |
| 12/21/2005 | ELECTRIC - FINAL | ROHAVER | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL BONDING JUMPER ACCROSS NON METALLIC A/C BELOW ROOF MECH 2) A/C NOT ON PLANS AND/OR ELECTRIC CALCULATIONS 3) INSTALL COVER PLATES RECEPTACLES SWITCHES ETC... 4) INSTALL LIGHT FIXTURE 5) POST ADDRESS NUMBERS ON HOUSE JACUZZI 6) RAISE PLUMBING VENTS ABOVE A/C UNIT FOR PROPER VENTING AND MECH VENT ALSO 7) KITCHEN COUNTER TOP RECEPTACLES NOT TO CODE 8) RAISE FLU PIPE 12" ABOVE PARAPET 9) INSTALL GAS AND H20 BONDS 10) MUST COMPLETE AND CALL IN ALL TRADES FOR FINALS 11) INSTALL STOOP 12) INSTALLL SAN-TEE AT VENT AND REDUCER TO TIE CONDENSATE DRAIN INTO ROOF VENT PIPE AND INSTALL TRAP ALSO 13) MUST COMPLETE ALL TRADES THEN RECALL ALL 14) STOPPED INSPECTION |
| 12/21/2005 | PLUMBING - GAS PRESS TEST FNL | ROHAVER | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/08/2006 | MECHANICAL - FINAL | JWEATHER | Approved | CANCELLED PER OWNER DIANA #904-1396 |
| 02/21/2006 | PLUMBING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 02/21/2006 | BUILDING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 02/22/2006 | PERMIT FINALED | JWEATHER | Approved |