Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T04CM03683
Permit Details
Apply Date:
08/10/2004
Applicant:
OSCAR SILVA
Description:
NEW:DUPLEX
Contractors:
- SUNDRY BUILDERS
Permit Reviews
Permit Number - T04CM03683
Permit Status: Final
Permit Description: NEW:DUPLEX
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/10/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 08/27/2004 | COMPLETED |
08/27/2004 | 3RD PARTY REVIEW-RESIDENTIAL | 08/27/2004 | COMPLETED |
08/27/2004 | POST 3RD PARTY REVIEW | 09/30/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM03683
Permit Status: Final
Permit Description: NEW:DUPLEX
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/10/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04CM03683
Permit Description: NEW:DUPLEX
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/15/2004 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
09/15/2004 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
09/22/2004 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
09/23/2004 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* 2- #4 COPPER UFERS 20'EACH |
09/23/2004 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :*/1)YARDWATER CORRECTIONS MADE OK. OK TO COVER. |
10/07/2004 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
10/21/2004 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection :* |
10/21/2004 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
10/25/2004 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection :* |
10/25/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
10/26/2004 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection :* |
10/27/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
10/29/2004 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)OVER HEAD WATER DISTRIBUTION OK 3)WASTE & VENT SYSTEM OK 4)CLOSET FLANGES OK |
11/08/2004 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection :* |
11/30/2004 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection :* OK TO CLEAR CABLE DROP ONLY NO METER /NO TEMP SERVICE. CORRECTIONS REQUIRED 1) UNTWIST GROUNDING CONDUCTORS AND LAND EACH CONDUCTOR INTO SEPARATE TERMINALS. DO NOT GROUP GROUNDS INTO A SINGLE TERMINAL. 2. TRIM CABLE ENDS TO ELIMINATE "SHINER" ENDS. 3. SUPPORT GROUND WIRES BY CLAMPING TO WALL. 4) YOU MAY ELIMINATE THE GROUND BOND TO COLD WATER PIPE. 5) SEPARATE ( UNTWIST) ROMEX GROUNDS AND LAND INTO INDIVIDUAL TERMINAL SCREW CLAMP. 6) TRIM CIRCUIT WIRES TO ELIMINATE "SHINER" AT CIRCUIT BRAKERS. THANK YOU. |
12/07/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO UNITS 1 & 2 |
12/08/2004 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection :*OK TO CLEAR |
12/08/2004 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | |
12/08/2004 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | |
12/08/2004 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :*/1)NOTICE INSIDE ELECTRIC SERVICE TO READ; "THIS BUILDING HAS NON-METALLIC WATER PIPING" 2)WHEN A DISHWASHER AIR BREAK FITTING IS OMITTED, THE DRAIN HOSE IS TO BE LOOPED TO WITHIN 2" OF DRAINBOARD HEIGHT 3)PLUMBING FINAL OK 4)OK FOR C/O PENDING ANY OTHER INSPECTION |
12/08/2004 | OUTDOOR LIGHTING FINAL | MCAPISTR | Approved | IVRS - Inspection :* |
12/09/2004 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
12/09/2004 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
12/10/2004 | PERMIT FINALED | JWEATHER | Approved | |
12/10/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |