Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Apply Date:
08/10/2004
Applicant:
OSCAR SILVA
Description:
NEW:DUPLEX
Contractors:
  • SUNDRY BUILDERS

Permit Reviews

Permit Number - T04CM03683
Permit Status: Final
Permit Description: NEW:DUPLEX
Start Date Submittal Complete Date Status  
08/10/2004 PLANS OK TO SUBMIT - 3RD PARTY 08/27/2004 COMPLETED Review Details
08/27/2004 3RD PARTY REVIEW-RESIDENTIAL 08/27/2004 COMPLETED Review Details
08/27/2004 POST 3RD PARTY REVIEW 09/30/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM03683
Permit Status: Final
Permit Description: NEW:DUPLEX
Total Outstanding Activity Conditions - 1
Date Name
08/10/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM03683
Permit Description: NEW:DUPLEX
Total Completed Inspections - 25
Date Description Inspector Results Comments
09/15/2004 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
09/15/2004 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
09/22/2004 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection :*
09/23/2004 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :* 2- #4 COPPER UFERS 20'EACH
09/23/2004 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*/1)YARDWATER CORRECTIONS MADE OK. OK TO COVER.
10/07/2004 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection :*
10/21/2004 U VALUE FOR WINDOW AMATHIES Approved IVRS - Inspection :*
10/21/2004 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
10/25/2004 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection :*
10/25/2004 FRAMING AMATHIES Approved IVRS - Inspection :*
10/26/2004 STUCCO MESH AMATHIES Approved IVRS - Inspection :*
10/27/2004 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
10/29/2004 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)OVER HEAD WATER DISTRIBUTION OK 3)WASTE & VENT SYSTEM OK 4)CLOSET FLANGES OK
11/08/2004 SHEET ROCK NAILING HLEYVA Approved IVRS - Inspection :*
11/30/2004 ELECTRIC - CABLE DROP MCAPISTR Approved IVRS - Inspection :* OK TO CLEAR CABLE DROP ONLY NO METER /NO TEMP SERVICE. CORRECTIONS REQUIRED 1) UNTWIST GROUNDING CONDUCTORS AND LAND EACH CONDUCTOR INTO SEPARATE TERMINALS. DO NOT GROUP GROUNDS INTO A SINGLE TERMINAL. 2. TRIM CABLE ENDS TO ELIMINATE "SHINER" ENDS. 3. SUPPORT GROUND WIRES BY CLAMPING TO WALL. 4) YOU MAY ELIMINATE THE GROUND BOND TO COLD WATER PIPE. 5) SEPARATE ( UNTWIST) ROMEX GROUNDS AND LAND INTO INDIVIDUAL TERMINAL SCREW CLAMP. 6) TRIM CIRCUIT WIRES TO ELIMINATE "SHINER" AT CIRCUIT BRAKERS. THANK YOU.
12/07/2004 TEP CLEARANCE - AM JKOZUCH Approved ECO UNITS 1 & 2
12/08/2004 ELECTRIC - FINAL MCAPISTR Approved IVRS - Inspection :*OK TO CLEAR
12/08/2004 PLUMBING - GAS PRESSURE TEST RMYERS Approved
12/08/2004 PLUMBING - GAS PRESS TEST FNL RMYERS Approved
12/08/2004 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*/1)NOTICE INSIDE ELECTRIC SERVICE TO READ; "THIS BUILDING HAS NON-METALLIC WATER PIPING" 2)WHEN A DISHWASHER AIR BREAK FITTING IS OMITTED, THE DRAIN HOSE IS TO BE LOOPED TO WITHIN 2" OF DRAINBOARD HEIGHT 3)PLUMBING FINAL OK 4)OK FOR C/O PENDING ANY OTHER INSPECTION
12/08/2004 OUTDOOR LIGHTING FINAL MCAPISTR Approved IVRS - Inspection :*
12/09/2004 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
12/09/2004 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
12/10/2004 PERMIT FINALED JWEATHER Approved
12/10/2004 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW