Permit Details

Status:
C of o
Type:
DUPLEX NEW
Address NEW:
240 E VALESKA RD #01
Apply Date:
07/30/2004
Applicant:
N/A
Description:
DUPLEX:TD#16-12-01
Contractors:
  • CRYSTAL HOMES AND DEVELOPMENT L L C

Permit Reviews

Permit Number - T04CM03526
Permit Status: C of o
Permit Description: DUPLEX:TD#16-12-01
Start Date Submittal Complete Date Status  
07/30/2004 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 07/30/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM03526
Permit Status: C of o
Permit Description: DUPLEX:TD#16-12-01
Total Outstanding Activity Conditions - 1
Date Name
07/30/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM03526
Permit Description: DUPLEX:TD#16-12-01
Total Completed Inspections - 24
Date Description Inspector Results Comments
09/23/2004 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection :*
09/30/2004 STEM WALL/RETAINING WALL AMATHIES Approved IVRS - Inspection :*APPROVED.
10/05/2004 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)NOTE: SHALL REMOVE TWO WAY C.O. FITTINGS ONE WITH FLOW AND THE OTHER REVERSE FLOW 3)OK TO BACKFILL TRENCH
10/13/2004 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection :*
10/13/2004 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection :*
11/01/2004 REINFORCED MASONRY PRE-GROUT HLEYVA Approved IVRS - Inspection :*
11/15/2004 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
12/29/2004 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) SUPPORT SUB-PANEL RIGIDLY ON TWO SIDES NOT JUST ONE
2) SUB-PANEL ON PLAN SHOWN TO BE FACING OUT INTO BEDROOM NOT INTO WASH ROOM-DRYER WILL NOT ALLOW CLEARANCE IN FRONT OF PANEL WHICH IS REQUIRED
3) RECEPTACLE IN FURN ROOM MISSING
4) KITCHEN EXHAUST FAN CANNOT BE ON KITCHEN APPLIANCE CIRCUIT
5) EX FANS IN BATHROOMS STAPLE WITH 12" OFF ENCLOSURE
12/30/2004 FRAMING AMATHIES Approved IVRS - Inspection :*
12/30/2004 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection :*
12/30/2004 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
12/31/2004 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) GAS PRESSURE TEST IS OK 4) OK FOR DRY WALL
01/13/2005 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection :*APPROVED.
02/15/2005 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection :*
03/24/2005 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) HCS SEWER MAIN TAP IS OK. 3) OK TO BACKFILL TRENCH.
04/12/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :* APPROVED
04/12/2005 PLUMBING - GAS PRESS TEST FNL TRINIVJR Approved IVRS - Inspection :*
04/12/2005 U VALUE FOR WINDOW AMATHIES Approved IVRS - Inspection :*
04/14/2005 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*OK TO CLEAR METER FOR UNIT #2 CALLED INTO OFFICE
04/15/2005 TEP CLEARANCE - AM JKOZUCH Approved ECO METER #2
04/15/2005 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection :*
04/20/2005 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection :* 1) PLUMBING FINAL IS OK. 2) OK FOR C OF O
05/05/2005 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :*
05/19/2005 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CERT OF OCC VIEW