Permit: T04CM03526
Permit Details
Apply Date:
07/30/2004
Applicant:
N/A
Description:
DUPLEX:TD#16-12-01
Contractors:
- CRYSTAL HOMES AND DEVELOPMENT L L C
Permit Reviews
Permit Number - T04CM03526
Permit Status: C of o
Permit Description: DUPLEX:TD#16-12-01
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/30/2004 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/30/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM03526
Permit Status: C of o
Permit Description: DUPLEX:TD#16-12-01
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/30/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM03526
Permit Description: DUPLEX:TD#16-12-01
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/23/2004 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
| 09/30/2004 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection :*APPROVED. |
| 10/05/2004 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)NOTE: SHALL REMOVE TWO WAY C.O. FITTINGS ONE WITH FLOW AND THE OTHER REVERSE FLOW 3)OK TO BACKFILL TRENCH |
| 10/13/2004 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
| 10/13/2004 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
| 11/01/2004 | REINFORCED MASONRY PRE-GROUT | HLEYVA | Approved | IVRS - Inspection :* |
| 11/15/2004 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/29/2004 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPORT SUB-PANEL RIGIDLY ON TWO SIDES NOT JUST ONE 2) SUB-PANEL ON PLAN SHOWN TO BE FACING OUT INTO BEDROOM NOT INTO WASH ROOM-DRYER WILL NOT ALLOW CLEARANCE IN FRONT OF PANEL WHICH IS REQUIRED 3) RECEPTACLE IN FURN ROOM MISSING 4) KITCHEN EXHAUST FAN CANNOT BE ON KITCHEN APPLIANCE CIRCUIT 5) EX FANS IN BATHROOMS STAPLE WITH 12" OFF ENCLOSURE |
| 12/30/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/30/2004 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection :* |
| 12/30/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 12/31/2004 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) GAS PRESSURE TEST IS OK 4) OK FOR DRY WALL |
| 01/13/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :*APPROVED. |
| 02/15/2005 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
| 03/24/2005 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) HCS SEWER MAIN TAP IS OK. 3) OK TO BACKFILL TRENCH. |
| 04/12/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* APPROVED |
| 04/12/2005 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | IVRS - Inspection :* |
| 04/12/2005 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection :* |
| 04/14/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :*OK TO CLEAR METER FOR UNIT #2 CALLED INTO OFFICE |
| 04/15/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO METER #2 |
| 04/15/2005 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection :* |
| 04/20/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) PLUMBING FINAL IS OK. 2) OK FOR C OF O |
| 05/05/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 05/19/2005 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved |