Permit: T04CM03526

Parcel: 13811045A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/20/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 1) PLUMBING FINAL IS OK. 2) OK FOR C OF O
04/15/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE NOTE #2 AS REQUESTED. CANNOT USE BRASS PLUGS ON ABS
2) SHALL PROVIDE COUNTER SUNK PLUGS FOR KITCHEN SINK C.O. THAT ARE ALREADY TAPED FOR A SCREW
04/12/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) C.O FOR KITCHEN SINKS REQUIRE MIN OFR 12' OF FRONTAL CLEARANCE. 2) C.O @ TWO WAY C.O IN PACKING LOT REQUIRES TRAFFIC RATED COVERS 3) SHALL CAP OFF FLEX LINES FOR GAS RANGE IF RANGE IS NOT INSTALLED @ TIME OF INSPECTION. 4) SHALL CALL IN YARD WATER LINE ITEM 3040 @ TIME OF FINAL REQUEST.