Permit: T04CM03412
Permit Details
Apply Date:
07/23/2004
Applicant:
LANNING, ROBERT SCOTT
Description:
RENOVATE:APARTMENT BUILDING
Architects:
- LANNING, ROBERT SCOTT
Contractors:
- KACHINA GENERAL CONTRACTORS L L C
Permit Reviews
Permit Number - T04CM03412
Permit Status: Final
Permit Description: RENOVATE:APARTMENT BUILDING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/03/2005 | 3RD PARTY REVIEW-REVISION/OTHER | 01/03/2005 | COMPLETED |
04/07/2005 | 3RD PARTY REVIEW-REVISION/OTHER | 04/07/2005 | COMPLETED |
07/23/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 07/29/2004 | COMPLETED |
07/29/2004 | 3RD PARTY REVIEW-COMMERCIAL | 08/30/2004 | COMPLETED |
08/30/2004 | POST 3RD PARTY REVIEW | 09/09/2004 | COMPLETED |
09/10/2004 | RESUBMITTAL | 09/14/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM03412
Permit Status: Final
Permit Description: RENOVATE:APARTMENT BUILDING
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/23/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04CM03412
Permit Description: RENOVATE:APARTMENT BUILDING
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/07/2004 | FRAMING | HLEYVA | Approved | IVRS - Inspection :* |
12/22/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :DENIED. DO NOT USE ALUMINUM FLEX ON DRYER VENTS. SECURE DRYER VENT IN WALL 1ST FLOOR. PROVIDE FHA STRAPES ON KITCHEN VENTS. BE SURE REFER LINES DON'T BLOCK ACCESS TO FAN COILS IN ATTIC. PROVIDE FHA STRAPS AT DRYER VENT ON 2ND FLOOR. SECURE EXHAUST VENTS IN ATTIC. See detailed listing on site.| 999* |
12/22/2004 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) PLEASE EXPLAIN AND PROVIDE PROOF FOR THE FOLLOWING: ALL BEDROOMS CIRCUITS MUST BE ON ARC FAULT CIRCUIT BREAKERS INCLUDING ALL LIGHTING AND OTHER 120/240 V APPARTATUS ( SMOKE DETECTORS ) 2) SPECIFICATIONS REQUIRE ALL SMOKE DETECTORS TO BE INTERCONNECTED TO ALARM SIMULTANEOUSLY. THIS MEANS ALL SMOKE ALARMS IN THE BLDG 3) PROVIDE MANUFACTURERS PROOF ALLOWING THE RECESSED LIGHT FIXTURE BALLASTS TO BE MOUNTED ON COMBUSTIBLE SURFACE 4) IS THERE A CENTRAL FIRE ALARM SYSTEM ? |
12/30/2004 | PLUMBING - ABOVE CEILING | RMYERS | Approved | (1) NO TEST ON ABS. (2) NOT INSTALLED PER PLAN. (3) SEE NOTE #3 ON PLUMBING NOTES. INSPECTION STOPPED. |
12/30/2004 | PLUMBING - INTERMEDIATE | RMYERS | Approved | (1) NO TEST ON ABS. (2) NOT INSTALLED PER PLAN. (3) SEE NOTE #3 ON PLUMBING NOTES. INSPECTION STOPPED. |
12/30/2004 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | NOT READY-(1) NO TEST ON ABS. (2) NOT INSTALLED PER PLAN. (3) SEE NOTE #3 ON PLUMBING NOTES. INSPECTION STOPPED. |
04/20/2005 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
05/10/2005 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* 1) 4" SDR 35 BLDG SEWER FROM 2 WAY CLEAN OUT TO TAPPED MAIN IN FIRST STREET OK. TAP OK WATER TEST OK. OK TO BACKFILL. |
10/11/2005 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
10/11/2005 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
10/14/2005 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
10/20/2005 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) PLUMBING FINAL OK 2) OK FOR C OF O PENDING ANY OTHER INSPECTION |
10/25/2005 | OUTDOOR LIGHTING FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
10/26/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
11/01/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
11/03/2005 | TEP CLEARANCE - PM | JKOZUCH | Approved | PER R MAJUTA ECO 1101,1102,1201, 1202 PLUS HOUSE METER |
11/18/2005 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | |
11/18/2005 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection :* |
11/18/2005 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* |
11/18/2005 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
11/21/2005 | SHEET ROCK NAILING | AMATHIES | Approved | |
11/21/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
11/30/2005 | PERMIT FINALED | BGRANT | Approved |