Status:
Final
Type:
MULTI FAMILY ALTERATION
Apply Date:
07/23/2004
Applicant:
LANNING, ROBERT SCOTT
Description:
RENOVATE:APARTMENT BUILDING
Architects:
  • LANNING, ROBERT SCOTT
Contractors:
  • KACHINA GENERAL CONTRACTORS L L C

Permit Reviews

Permit Number - T04CM03412
Permit Status: Final
Permit Description: RENOVATE:APARTMENT BUILDING
Start Date Submittal Complete Date Status  
01/03/2005 3RD PARTY REVIEW-REVISION/OTHER 01/03/2005 COMPLETED Review Details
04/07/2005 3RD PARTY REVIEW-REVISION/OTHER 04/07/2005 COMPLETED Review Details
07/23/2004 PLANS OK TO SUBMIT - 3RD PARTY 07/29/2004 COMPLETED Review Details
07/29/2004 3RD PARTY REVIEW-COMMERCIAL 08/30/2004 COMPLETED Review Details
08/30/2004 POST 3RD PARTY REVIEW 09/09/2004 COMPLETED Review Details
09/10/2004 RESUBMITTAL 09/14/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM03412
Permit Status: Final
Permit Description: RENOVATE:APARTMENT BUILDING
Total Outstanding Activity Conditions - 1
Date Name
07/23/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM03412
Permit Description: RENOVATE:APARTMENT BUILDING
Total Completed Inspections - 23
Date Description Inspector Results Comments
12/07/2004 FRAMING HLEYVA Approved IVRS - Inspection :*
12/22/2004 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :DENIED. DO NOT USE ALUMINUM FLEX ON DRYER VENTS. SECURE DRYER VENT IN WALL 1ST FLOOR. PROVIDE FHA STRAPES ON KITCHEN VENTS. BE SURE REFER LINES DON'T BLOCK ACCESS TO FAN COILS IN ATTIC. PROVIDE FHA STRAPS AT DRYER VENT ON 2ND FLOOR. SECURE EXHAUST VENTS IN ATTIC.
See detailed listing on site.| 999*
12/22/2004 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) PLEASE EXPLAIN AND PROVIDE PROOF FOR THE FOLLOWING: ALL BEDROOMS CIRCUITS MUST BE ON ARC FAULT CIRCUIT BREAKERS INCLUDING ALL LIGHTING AND OTHER 120/240 V APPARTATUS ( SMOKE DETECTORS )
2) SPECIFICATIONS REQUIRE ALL SMOKE DETECTORS TO BE INTERCONNECTED TO ALARM SIMULTANEOUSLY. THIS MEANS ALL SMOKE ALARMS IN THE BLDG
3) PROVIDE MANUFACTURERS PROOF ALLOWING THE RECESSED LIGHT FIXTURE BALLASTS TO BE MOUNTED ON COMBUSTIBLE SURFACE
4) IS THERE A CENTRAL FIRE ALARM SYSTEM ?
12/30/2004 PLUMBING - ABOVE CEILING RMYERS Approved (1) NO TEST ON ABS. (2) NOT INSTALLED PER PLAN. (3) SEE NOTE #3 ON PLUMBING NOTES. INSPECTION STOPPED.
12/30/2004 PLUMBING - INTERMEDIATE RMYERS Approved (1) NO TEST ON ABS. (2) NOT INSTALLED PER PLAN. (3) SEE NOTE #3 ON PLUMBING NOTES. INSPECTION STOPPED.
12/30/2004 PLUMBING - ROUGH, SOIL RMYERS Approved NOT READY-(1) NO TEST ON ABS. (2) NOT INSTALLED PER PLAN. (3) SEE NOTE #3 ON PLUMBING NOTES. INSPECTION STOPPED.
04/20/2005 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
05/10/2005 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :* 1) 4" SDR 35 BLDG SEWER FROM 2 WAY CLEAN OUT TO TAPPED MAIN IN FIRST STREET OK. TAP OK WATER TEST OK. OK TO BACKFILL.
10/11/2005 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
10/11/2005 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
10/14/2005 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
10/20/2005 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1) PLUMBING FINAL OK
2) OK FOR C OF O PENDING ANY OTHER INSPECTION
10/25/2005 OUTDOOR LIGHTING FINAL RMAJUTA Approved IVRS - Inspection :*
10/26/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
11/01/2005 TEP CLEARANCE - AM JKOZUCH Approved ECO
11/03/2005 TEP CLEARANCE - PM JKOZUCH Approved PER R MAJUTA ECO 1101,1102,1201, 1202 PLUS HOUSE METER
11/18/2005 ELECTRIC - CABLE DROP RMAJUTA Approved
11/18/2005 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection :*
11/18/2005 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :*
11/18/2005 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection :*
11/21/2005 SHEET ROCK NAILING AMATHIES Approved
11/21/2005 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :*
11/30/2005 PERMIT FINALED BGRANT Approved