Permit: T04CM03257
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
2001 W CALLE CAMPANA DE PLATA
Address NEW:
2001 W CALLE CAMPANA DE PLATA
Apply Date:
07/14/2004
Applicant:
MARC OCHOA
Description:
ENCLOSE:GARAGE TO ROOM:GAS LINE
Outstanding Activity Conditions
Permit Number - T04CM03257
Permit Status: Expired
Permit Description: ENCLOSE:GARAGE TO ROOM:GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/14/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04CM03257
Permite Description: ENCLOSE:GARAGE TO ROOM:GAS LINE
Total Outstanding Inspections - 12
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| MECHANICAL - FINAL | N/A | Not Inspected | ||
| 02/09/2005 | BUILDING PRE-SLAB | N/A | Partial Approval | IVRS - Inspection :* |
| 03/10/2005 | EXT METAL CLIPS/EXT SHEATHING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP HEADERS AT BEARING 2) NEED ELECTRIC SERVICE INCREASE ON CARD 3) RELOCATION OF H20 HEATER, RANGE, ALL WATER PIPING AND EXHAUST HOOD KITCHEN ISLAND 4) INSTALL 1" RISER AT METER 5) SUBMIT REVISED GAS PLANS FOR APPROVAL (SIZE OF PIPING LENGTH OF RUN AND APPLIANCES) 6) MUST PRIME AND WRAP ALL UNCOATED SCOTCH KOTE GAS PIPING 7) INSTALL GAS COCK BEFORE UNION EXTERIOR 8) OPEN UP WALLS TO EXPOSE ALL ELECTRIC ON PLAN (FRONT ENTRY FRAMING ONLY 9) PLAN SHOWS RIGHT AND LEFT ELEVATIONS 4' OPENINGS FRONT ENTRY (6' EXISTS) AND PARAPET TO STOP ON NORTH SIDE BEFORE PEAK EXISTING ROOF 10) PLAN CALLS FOR NEW 3 1/8" X 10 1/8" GLU LAM BEAM 11) NEED TO EXPOSE BACKSIDE OF LEDGERS TO VERITY A35'S 12) NEED TO EXPOSE PARAPET WALL TO VERIFY BOTTOM PLATE ATTACHMENT TO EXISTING 13) BOTTOM WOOD PLATES TO HAVE FULL BERAING ON CONCRETE AND INSTALL PLATE BOLTS MINIMUM 2 BOLTS PER PLATE 1/2" DIAMETER |
| 03/10/2005 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/10/2005 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/10/2005 | MECHANICAL - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 04/26/2005 | EXCAVATION/LAYOUT REBAR & ZON | N/A | Not ready for Inspection | IVRS - Inspection :* 1) ELECTRIC INSIDE ENTRY WAY TO BE IN BOX AND SECURE 2) REPLACE DAMAGED WIRES SAME LOCATION 3) UNABLE TO VERIFY EXISTING ELECTRIC GROUNDING WILL NEED TO DRIVE 2 8' GROUND RODS MINIMUM 6' APART 4) REAR PORCH SLAB POURED WITHOUT INSPECTION APPROVAL, EXPOSE CONCRETE FTGS AT POST BASES |
| 04/26/2005 | ROOF NAILING | N/A | Partial Approval | IVRS - Inspection :* 1) FRONT ENTRY |
| 05/13/2005 | FRAMING | N/A | Partial Approval | IVRS - Inspection :* 1) PARTIAL FRAMING PENDING TWO BAY WINDOWS |
| 06/10/2005 | SHEET ROCK NAILING | N/A | Not ready for Inspection | IVRS - Inspection :* 1) REAR PORCH FRAMING INCOMPLETE 2) BAY WINDOWS INCOMPLETE 3) PLAN CALLS FOR 5/8" DRYWALL NEW ENTRY FOYER |
Completed Inspections
Permit Status: Expired
Permit Number: T04CM03257
Permit Description: ENCLOSE:GARAGE TO ROOM:GAS LINE
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2005 | ELECTRIC - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection :* |
| 06/10/2005 | STUCCO MESH | ROHAVER | Approved | IVRS - Inspection :* |