Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
2102 N NORTON AV
Address NEW:
2102 N NORTON AV
Apply Date:
06/11/2004
Applicant:
DAVID LEE
Description:
ADDITION:MASTER BEDROOM & BATH W/ GAME ROOM

Permit Reviews

Permit Number - T04CM02667
Permit Status: Final
Permit Description: ADDITION:MASTER BEDROOM & BATH W/ GAME ROOM
Start Date Submittal Complete Date Status  
01/03/2005 REVISION - WALK THRU 01/06/2005 COMPLETED Review Details
06/11/2004 RESIDENTIAL BLDG/ZONING/ENGINE/WWM 07/02/2004 COMPLETED Review Details
07/02/2004 RESIDENTIAL BLDG/ZONING/ENGINE/WWM 08/04/2004 COMPLETED Review Details
08/12/2004 RESUBMITTAL 08/17/2004 COMPLETED Review Details
12/08/2004 REVISION - WALK THRU 12/08/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM02667
Permit Status: Final
Permit Description: ADDITION:MASTER BEDROOM & BATH W/ GAME ROOM
Total Outstanding Activity Conditions - 1
Date Name
06/11/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM02667
Permit Description: ADDITION:MASTER BEDROOM & BATH W/ GAME ROOM
Total Completed Inspections - 18
Date Description Inspector Results Comments
08/27/2004 EXCAVATION/LAYOUT REBAR & ZON BSTEVENS Approved IVRS - Inspection :*
09/10/2004 PLUMBING - ROUGH, SOIL BSTEVENS Approved IVRS - Inspection :*
09/10/2004 BUILDING PRE-SLAB BSTEVENS Approved IVRS - Inspection :*
09/10/2004 STEM WALL/RETAINING WALL BSTEVENS Approved IVRS - Inspection :*
10/14/2004 REINFORCED MASONRY PRE-GROUT BSTEVENS Approved IVRS - Inspection :*
12/03/2004 ROOF NAILING BSTEVENS Approved IVRS - Inspection :*
12/22/2004 FRAMING JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*/1)ROOF FRAME NOT PER PLAN. PLAN CALLS FOR JOIST TO BE EAST WEST BY EXISTING HOUSE BUT ARE INSTALLED NORTH SOUTH AND ARE BEARING ON FRAME WALL NOT ANCHORED PER CODE. HAVE PLAN REVISED TO AS BUILT 2)POST IS MISSING FROM PRE EXISTING SOUTH ROOM AND A SITE BUILT POST AND BEAM INSTALLED. HAVE PLAN REVISED TO AS BUILT 3)PLAN CALLS FOR 4X4 POSTS NOT DOUBLE 2X4 POSTS 4)PLAN CALLS FOR 6X8 BEAM AT 8' DOOR-PRESENTLY MO??ONARY - REFUSE PLAN 5)5/3 NOT COMPLING WITH 6)WEST DUCT WORK NOT PER PLAN-REVISE PLAN 7)NO DWV PLUMBING WATER TEST. FILL ALL TO ROOF WITH WATER 8)PLAN CALLS FOR COPPER PLUMBING PEX USE A BUILD TO PLAN OR FEVISE TO AS BUILT 9)GAS LINE MUST BE ELECTRICALLY BONDED 10)WALK IN CLOSET MISSING LIGHTS. SEE PLAN 11)COULD NOT FIND GAS PRESSURE TEST. STOPPED INSPECTION - TOO MANY ITEMS
12/22/2004 PLUMBING - GAS PRESSURE TEST JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/22/2004 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/22/2004 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/22/2004 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/11/2005 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection :*
01/24/2005 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
02/10/2005 BUILDING - FINAL RCAMACHO Approved IVRS - Inspection :*
02/10/2005 MECHANICAL - FINAL RCAMACHO Approved IVRS - Inspection :*
02/10/2005 PLUMBING - FINAL RCAMACHO Approved IVRS - Inspection :*
02/10/2005 ELECTRIC - FINAL RCAMACHO Approved IVRS - Inspection :*
02/11/2005 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW