Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T04CM02667
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/06/2004 | Andrew Connor | NPPO | REVIEW | Passed | |
| 07/06/2004 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 07/08/2004 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 08/02/2004 | Peter McLaughlin | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: David Lee 8550 N. Burke Ave Tucson, AZ 85742 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T04CM02667 Addition 2102 N. Norton Ave. TRANSMITTAL: August 3, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Per LUC 3.5.7.1.H, for all single family dwellings in the R-1 zone with five (5) or more bedrooms, all parking and maneuvering must be located on-site, either in a side or rear perimeter yard. The vehicular use area must be improved, which includes surfacing, striping, and provision of barriers, in conformance with Development Standard 3-05.0. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. Per LUC 6.2.2 the definition of "bedroom" reads as follows: Any enclosed room which has a minimum area of sixty (60) square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms. Revise site plan to comply with regulations for 5 bedrooms. If the requirements of LUC 3.5.7.1.H cannot be met, Board of Adjustment variance approval is required. If a variance is sought, include the variance case number, date of approval and conditions imposed on the site plan. Provide a copy of variance approval letter at time of permitting. LUC 3.5.7.1.H 2. Per LUC 3.2.6.4, the perimeter yard "AA" building setback is required to be the greater of 6 feet or 2/3 height of exterior structure wall. The proposed addition is as close as five (5) feet from the south lot line. An approved Lot Development Option (LDO) application is required to allow the proposed setback encroachment. If a Board of Adjustment Variance is sought (see comment 1), the south lot line building setback issue can be included in the variance request to avoid paying two separate fees. LUC 3.2.6.4 3. For setback verification purposes, add the height (above design grade, not above finished floor) of exterior structure walls along each side of the proposed addition. LUC 3.2.6.4 4. The lot coverage calcs list an existing guest house. Please clarify by labeling the existing guest house on the plan. 5. The site plan (sheet 1) and framing plan (sheet 4) show a door leading directly from the sitting room to the adjacent closet, but the floor plan (sheet 2) and mechanical/electrical plans (sheets 5 & 6) do not show the door. Revise all plans to be consistent. 6. Add the name of the owner(s) of the property to the site plan. If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 08/02/2004 | Neil Saunders | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - T04CM02667 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints shall be returned. 2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure all corrections have been made, are complete and have been coordinated on all-applicable details and notes. Floor Plan 1. 1. Note that bathtub and shower enclosures shall be finished per P2710 with ceramic tile, or a listed enclosure, to a height of 72" above the drain per R702.4 and R307.2. 2. Note and specify that shower enclosures shall have a minimum finished interior area of 1,024 square inches and shall be capable of encompassing a minimum 30" circle per UPC SEC. 410.0. All glass enclosures shall be tempered. 3. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per R307.2 (figure). Foundation Plan 1. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used per table R401.4.1, a soils report is not required. It is up to the designer / homebuilder to be aware of the soil and conditions of the site. 2. Provide landings at exterior doors per R312. Structural Plans 1. Lintel over 6' door opening should be 4"x3 ½ "x 5/16". 2. Note roofing material. 3. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply. Plumbing, Mechanical and Electrical Plans 1. Clotheswasher = 6 f.u. Redo fixture unit summary and provide total developed length of supply line. 2. Condendsate line is not allowed to drain into a vent. Reroute condensate lines. 3. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type. 4. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code. 5. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute. 6. Callout insulation in ceiling. 7. Size return air duct for system #2. 14" minimum. 8. Bathroom GFI's must be on dedicated 20-amp circuit. Remove outside GFI's from circuit #17. 9. At least one wall switch controlled light or outlet must be provided at outdoor entrances or exits and all habitable rooms per E3801. Exterior door in sitting room. 10. All receptacle outlets within 6' of a wet bar or kitchen sink shall have ground fault circuit interrupting protection. Note on the drawings at each outlet requiring such protection, per E3802. 11. Is noted electrical service relocated from location shown on site plan? If so, provide note. ANY QUESTIONS PLEASE CONTACT NEIL SAUNDERS @ 791-5550 x2208. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/04/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 08/04/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |