Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address NEW:
2990 N CAMPBELL AV
Apply Date:
03/12/2004
Applicant:
THE ARCHITECTURE CO.
Description:
NEW:RESTAURANT SHELL
Contractors:
  • PRESIDIO CONSTRUCTION COMPANY

Permit Reviews

Permit Number - T04CM01180
Permit Status: Final
Permit Description: NEW:RESTAURANT SHELL
Start Date Submittal Complete Date Status  
02/04/2005 3RD PARTY REVIEW-REVISION/OTHER 02/07/2005 COMPLETED Review Details
02/25/2005 3RD PARTY REVIEW-REVISION/OTHER 03/21/2005 COMPLETED Review Details
03/12/2004 PLANS OK TO SUBMIT - SITE 03/12/2004 COMPLETED Review Details
03/12/2004 SITE 04/09/2004 COMPLETED Review Details
03/25/2005 3RD PARTY REVIEW-REVISION/OTHER 03/25/2005 COMPLETED Review Details
03/25/2005 POST 3RD PARTY REVIEW 03/30/2005 COMPLETED Review Details
05/07/2004 PLANS OK TO SUBMIT - 3RD PARTY 05/10/2004 COMPLETED Review Details
05/18/2005 3RD PARTY REVIEW-REVISION/OTHER 05/19/2005 COMPLETED Review Details
06/03/2004 RESUBMITTAL - SITE 07/14/2004 COMPLETED Review Details
06/25/2004 3RD PARTY REVIEW-COMMERCIAL 06/28/2004 COMPLETED Review Details
06/28/2004 POST 3RD PARTY REVIEW 07/08/2004 COMPLETED Review Details
07/13/2004 RESUBMITTAL 07/14/2004 COMPLETED Review Details
07/13/2005 3RD PARTY REVIEW-REVISION/OTHER 07/15/2005 COMPLETED Review Details
07/22/2005 REVISION 07/29/2005 COMPLETED Review Details
08/31/2005 REVISION 08/31/2005 COMPLETED Review Details
12/01/2004 3RD PARTY REVIEW-REVISION/OTHER 12/08/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM01180
Permit Status: Final
Permit Description: NEW:RESTAURANT SHELL
Total Outstanding Activity Conditions - 1
Date Name
03/12/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM01180
Permit Description: NEW:RESTAURANT SHELL
Total Completed Inspections - 45
Date Description Inspector Results Comments
09/13/2004 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :*/ 1) 3/0 COPPER UFER
09/27/2004 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*PARTIAL APPROVAL. EXCLUDES 9 COLUMNS.
10/06/2004 EXCAVATION/LAYOUT REBAR & ZON HLEYVA Approved IVRS - Inspection :*/OK COLUMN @ HORT? - ALL 7
10/12/2004 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*/1)NOT INSTALLED PER PLAN. REDLINES ON SITE. OK TO COVER SUBJ. TO REVISED PLAN
12/29/2004 REINFORCED MASONRY PRE-GROUT HLEYVA Approved IVRS - Inspection :*
1) OK 2ND LIFT AT 2ND FLOOR NORTH, SOUTH AND EAST WALLS
12/29/2004 BUILDING PRE-SLAB HLEYVA Approved IVRS - Inspection :*
1) OK 2 FTGS AT DISMISSING WALLS-NORTH AND SOUTH
01/31/2005 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
02/01/2005 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
02/01/2005 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
03/17/2005 FRAMING AMATHIES Approved IVRS - Inspection :* APPROVED
03/24/2005 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection :*
04/21/2005 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :* ROOF DRAINS OK
04/26/2005 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
05/17/2005 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
06/30/2005 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :* UNITS # 110, 120,130,140 SITE GAS OK. PRESSURE TEST OK. CONTINUED PIPING SUBJECT TO TI PERMITS.
07/25/2005 TEP CLEARANCE - AM RMAJUTA Approved OK ELEVATOR SERVICE PER SUBA
07/25/2005 ELECTRIC - CONSTRUCTION POWER RMAJUTA Approved IVRS - Inspection :*
BOND POSTED
OK TO CLEAR ECO
07/25/2005 ELECTRIC - TEMPORARY SERVICE RMAJUTA Approved IVRS - Inspection :*
08/04/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved
08/04/2005 MECHANICAL - ABOVE CEILING CWILLIAM Approved
08/04/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
SHELL HAS NO INSPECTIONS
04035 - NO INSPECTIONS
04036 - NO INSPECTIONS
APPROVED ONLY 04090 - SHELL HAS A/C ROOF TOP UNITS, REMOTE A/C UNITS & SUSPENDED FAN COILS
VARIOUS UTILITIES ARE CONNECTED NOT THE SAME TO ALL.
ALL UNITS COMPLETED ON EACH T.I. COMPLETION AND REQUIRES INSPECTIONS THEN .
08/09/2005 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
08/09/2005 OUTDOOR LIGHTING FINAL RSUBA Approved IVRS - Inspection :*
08/09/2005 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :*
08/09/2005 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*
08/09/2005 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*
08/09/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :* SHELL ONLY
08/12/2005 ENGINEERING - FINAL MRUSSO Approved C OF O FOR ENGINEERING APPROVED.
08/12/2005 FIRE - FINAL LTHOMAS Approved
08/12/2005 FIRE SPKLR - FINAL LTHOMAS Approved
08/16/2005 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
09/01/2005 PLUMBING - SEWER HCS CONNECT RMYERS Approved
09/01/2005 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
OK FOR C OF O PENDING ANY OTHER INSPECTION
09/01/2005 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
09/01/2005 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
09/01/2005 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
09/09/2005 ELECTRIC - UNDERGROUND RSUBA Approved
09/09/2005 ELECTRIC - CABLE DROP RSUBA Approved
09/21/2005 BUILDING ABOVE CEILING AQUIROZ Approved
09/21/2005 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
09/21/2005 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
09/21/2005 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
09/22/2005 PERMIT FINALED JMORALES Approved
09/22/2005 MECHANICAL - PROGRESS CWILLIAM Approved
09/22/2005 ELECTRIC - TEMP POWER FOR TEST RSUBA Approved

Documents

File Name Document Type  
STRUCCALC.TIF DOCUMENTS VIEW
STRUCCALCREVISED.TIF DOCUMENTS VIEW
GEOTECHENGRPT.TIF DOCUMENTS VIEW
REVISEDTRUSSCALC.TIF DOCUMENTS VIEW
SPECIALINSPRPT.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW