Permit: T04CM00533
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
1001 E 17TH ST BLDG #1
Address NEW:
1001 E 17TH ST BLDG #1
Apply Date:
02/05/2004
Applicant:
PAULUS, ROBERT FRANCIS
Description:
NEW:CONDOMINUIMS #101-131 201-216 230 231
Contractors:
- CALIBER WEST L L C
Permit Reviews
Permit Number - T04CM00533
Permit Status: C of o
Permit Description: NEW:CONDOMINUIMS #101-131 201-216 230 231
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/05/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 02/05/2004 | COMPLETED |
| 02/05/2004 | 3RD PARTY REVIEW-COMMERCIAL TI | 02/18/2004 | COMPLETED |
| 03/08/2004 | 3RD PARTY REVIEW-COMMERCIAL | 03/30/2004 | COMPLETED |
| 05/11/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 06/01/2004 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM00533
Permit Description: NEW:CONDOMINUIMS #101-131 201-216 230 231
Total Completed Inspections - 44
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2004 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :* |
| 07/09/2004 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
| 07/13/2004 | PLUMBING - ROOF DRAINS | RRICH | Approved | IVRS - Inspection :*/ 1) 6" BLDG SEWER STUBBED 2' OUTSIDE BLDG 6" BLDG DRAIN UNDERGROUND BACK TO WASTE AND VENT ONLY FOR 110, 111, 112, 113, 114, 115, 116, 111B, 113B AND 115B WATER TEST OK 2) NEED TO SEE 2-WAY BLDG CLEANOUT INSTALLATION 3) 6" RWL + 4" RWL UNDERGROUND WATER TEST TO 2" OUTSIDE BLDG BETWEEN CENTER LINE 6+7 AND SOUTH OF UNIT 111 OK 4) 4" RWL UNDERGROUND WATER TEST TO 2' OUTSIDE BLDG BETWEEN CENTER LINE 8+11 SOUTH OF 113+115 OK |
| 08/11/2004 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection :* |
| 08/18/2004 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :*/ 1) ENTRY STEPS |
| 08/26/2004 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection :* |
| 08/31/2004 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection :SOIL WATER TEST IS OK WASTE AND VENT SYSTEM IS OK THIS INSPECTION FOR WASTE AND VENT ONLY |
| 10/26/2004 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :*/ 1) "D" BLDG OK |
| 10/27/2004 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* |
| 11/02/2004 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :*/OK U.G. SECONDARYS & COMM CONDUITS AT SOUTH OF BLD #1 |
| 11/10/2004 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | 1) UNIT 124, 125, 126 AND 127 BLDG E |
| 11/10/2004 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection :* |
| 11/10/2004 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection :* |
| 11/17/2004 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection :*/1)AIR PRESSURE TEST IS OK. 2)YARD WATER LINE IS OK AS NOTED ON PLAN 3)OK TO BACKFILL TRENCH |
| 11/24/2004 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :*/ 1) SECTION "C" |
| 12/10/2004 | STUCCO MESH | AMATHIES | Approved | |
| 12/17/2004 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | |
| 12/20/2004 | PLUMBING - INTERMEDIATE | IVR USER | Approved | IVRS - AP canceled/1)PROVIDE CORRECT FALL ON ALL DRAINAGE PIPING 1/4" PER FOOT 2)PROVIDE 2 PIPE DIAMETORS AT SANTEE TO P-TRAP CONNECTION 3)CORRECT LEAK IN DWV PIPING. 4)PROVIDE IN WRITTING OR CORRECT NOTCHING AND OVERSIZE HOLE IN FLOOR JOIST. (3RD FLOOR CEILING, 4TH FLOOR AT REST ROOM AREA) NOT A COMPLETE LIST |
| 12/20/2004 | ELECTRIC - PROGRESS | DSANTACR | Approved | IVRS - Inspection :* 1) OK TO CLEAR HOUSE PANEL HP1 SUBJECT TO BOND POSTING-TEMP POWER FOR TEST |
| 12/21/2004 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :*PARTIAL APPROVAL. OK WALLS AND CEILINGS BLD. #1 "B" 3RD AND 4TH LEVEL. |
| 12/21/2004 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/21/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/23/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :*/BLDG B 3RD & 4TH FLOOR OK FOR SHEET ROCK. PROVIDE PLATE STRAPS PRIOR TO SHEET ROCK |
| 03/03/2005 | FIRE - ALARM FINAL | LTHOMAS | Approved | |
| 03/03/2005 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 03/03/2005 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 03/03/2005 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 03/04/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 03/04/2005 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 03/09/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 03/31/2005 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 03/31/2005 | RIGHT OF WAY - FINAL | THARVISO | Approved | |
| 03/31/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 03/31/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 04/05/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO 121 BLD 1 |
| 04/11/2005 | ELECTRIC - UFER | DSANTACR | Approved | |
| 04/11/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 04/12/2005 | MECHANICAL - PROGRESS | CWILLIAM | Approved | |
| 04/12/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 04/14/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) PLBG. FINAL IS OK FOR UNITS # 102, 113. THIS COMPLETES FINAL FOR ALL OF BLDG 1 2) OK FOR C OF O |
| 04/14/2005 | U VALUE FOR WINDOW | AMATHIES | Approved | |
| 04/14/2005 | BUILDING - PROGRESS | AMATHIES | Approved | |
| 04/14/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 04/14/2005 | NPPO - FINAL | ACONNOR | Approved |