Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM00533
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/14/2005 | PLUMBING - INTERMEDIATE | Approved | ||
| 01/03/2005 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - AP canceled | |
| 12/20/2004 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - AP canceled/1)PROVIDE CORRECT FALL ON ALL DRAINAGE PIPING 1/4" PER FOOT 2)PROVIDE 2 PIPE DIAMETORS AT SANTEE TO P-TRAP CONNECTION 3)CORRECT LEAK IN DWV PIPING. 4)PROVIDE IN WRITTING OR CORRECT NOTCHING AND OVERSIZE HOLE IN FLOOR JOIST. (3RD FLOOR CEILING, 4TH FLOOR AT REST ROOM AREA) NOT A COMPLETE LIST | |
| 12/16/2004 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - AP canceled | |
| 12/10/2004 | PLUMBING - INTERMEDIATE | Partial Approval | 1) SOIL WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) THIS INSPECTION IS FOR 1ST AND 2ND FLOOR ONLY |
|
| 12/09/2004 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - AP canceled | |
| 12/03/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | ||
| 12/02/2004 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - AP canceled | |
| 11/26/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | DO NOT CALL UNTIL YOU ARE READY | |
| 11/16/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/1)AIR PRESSURE TEST OF 50 LBS FOR OVERHEAD WATER DISTRIBUTION IS OK FOR BLDG. D & E ONLY 2) OK FOR DRYWALL UPON BLDG INSPECTORS APPROVAL | |
| 11/15/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/DOCUMENTATION ON PARTIAL INSPECTIONS INCOMPLETE. 2)BLDG ONE SECTION "1" CPVC NOT INSTALLED PER APPROVED PLAN. INSTALL HANGERS AND SUPPORTS PER TABLE 3-1 94 APC 3)DWV BLDG ONE LEVEL TWO SECTION E. NOT READY- PLEASE HAVE ACCESS AVAILABLE AT TIME OF INSPECTION | |
| 11/10/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/1)SOIL WATER TEST IS OK FOR BLDG 1 SECTION D LEVEL 1 & 2 AND SECTION E LEVEL 1 2)WASTE & VENT SYSTEM OK. 3)THIS INSPECTION IS FOR DWV SYSTEM ONLY | |
| 10/27/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 10/15/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) BLDG 1 SECTION A CLOSET FLANGES OK 2) WASTE AND VENT THRU ROOF WATER TEST OK 3) 80 PSI AIR TEST ON H20 PIPING IN UNITS ONLY OK 4) ALL PIPING TO BE SUPPORTED WITH APPROVED METHODS AND MATERIALS 5) NEED TO SE P-8 FLOOR SINK INSTALLATIONS 6) TRANSITION TO COPPER OR FIRE RATED PIPING AT PENETRATION OF FIREWALL MAYBE REQUIRED | |
| 10/14/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* HAVE AIR OR WATER TEST ON @ TIME OF INSP. | |
| 09/09/2004 | PLUMBING - INTERMEDIATE | Partial Approval | 1) OVERHEAD WATER DISTRIBUTION IS OK | |
| 08/31/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) WET VENTING IS FOR VERTICAL DRAINAGE ONLY 2) SHALL PROVIDE DRAINAGE FITTINGS 3) FOR KITCHEN RE-VENTS WHEN LOCATED BELOW FLOOD RIM LEVEL 3) RETEST SYSTEM |
|
| 08/04/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT READY FOR INSPECTION |