Permit: T04CM00213
Permit Details
Status:
Expired
Type:
DUPLEX ALTERATION
Address:
2638 N BALBOA AV #01
Address NEW:
2638 N BALBOA AV #01
Apply Date:
01/20/2004
Applicant:
N/A
Description:
REMODEL:DUPLEX T04VL00018
Contractors:
- PERKINS CARPENTRY AND REMODELING L L C
Permit Reviews
Permit Number - T04CM00213
Permit Status: Expired
Permit Description: REMODEL:DUPLEX T04VL00018
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/20/2004 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 05/04/2004 | COMPLETED |
| 05/04/2004 | RESIDENTIAL BLDG/WWM | 05/28/2004 | COMPLETED |
| 07/15/2004 | RESUBMITTAL | 10/11/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM00213
Permit Status: Expired
Permit Description: REMODEL:DUPLEX T04VL00018
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/20/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04CM00213
Permite Description: REMODEL:DUPLEX T04VL00018
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PLUMBING - FINAL | N/A | Not Inspected |
Completed Inspections
Permit Status: Expired
Permit Number: T04CM00213
Permit Description: REMODEL:DUPLEX T04VL00018
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2004 | ELECTRIC - CONSTRUCTION POWER | MCAPISTR | Approved | IVRS - Inspection :* OK TO CLEAR |
| 12/07/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | TEMP CONST POWER |
| 12/17/2004 | FRAMING | BSTEVENS | Approved | IVRS - Inspection :* |
| 12/23/2004 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection :* 1) OK TO DRYWALL |
| 12/27/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999*/PROVIDE DAMPERS IN PLENUMS AT TOP OF FURNACE & AT EVAP. COOLERS. PROVIDE BATHROOMN EXHAUST FANS. EXTEND LOW COMBUSTION AIR TO WITHIN 12" OF FURNACE PLATFORMS. REPLACE WATER HEATER VENT W/DOUBLE WALL & PROVIDE MIN. 1" CLEARANCE FROM COMBUSTIBLES. PROVIDE HIGH COMBUSTION AIR FOR WATER HEATER. HAVE PLUMBING INTERMEDIATE & FINAL ADDED TO PERMIT & ALSO GAS PRESSURE TEST. PROVIDE AN ENCLOSURE FOR WATER HEATER. |
| 01/07/2005 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :*/1)PRESSURE TEST OK 2)TAKE OUT PERMIT FOR NEW WATER HEATERS 3)OK TO COVER |
| 02/22/2005 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* APPROVED |
| 08/15/2005 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 08/16/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 09/27/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |