Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T04BU02490
Permit Details
Apply Date:
10/12/2004
Applicant:
RICK ENGINEERING
Description:
GRADING:19526CY CUT & 2915CY FILL
Contractors:
- TOFEL CONSTURCTION
Permit Reviews
Permit Number - T04BU02490
Permit Status: Final
Permit Description: GRADING:19526CY CUT & 2915CY FILL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/10/2005 | RESUBMITTAL - GRADING ALL | 06/27/2005 | COMPLETED |
06/27/2005 | RESUBMITTAL - GRADING | 05/01/2006 | COMPLETED |
09/22/2006 | REVISION - GRADING | 09/22/2006 | COMPLETED |
10/12/2004 | PLANS OK TO SUBMIT - GRADING | 10/12/2004 | COMPLETED |
10/12/2005 | REVISION - GRADING | 10/13/2005 | COMPLETED |
10/13/2004 | GRADING | 11/15/2004 | COMPLETED |
10/13/2005 | REVISION - GRADING | 11/17/2005 | COMPLETED |
11/23/2004 | RESUBMITTAL - GRADING ALL | 12/22/2004 | COMPLETED |
11/23/2005 | REVISION - GRADING | 12/29/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04BU02490
Permit Status: Final
Permit Description: GRADING:19526CY CUT & 2915CY FILL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/12/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04BU02490
Permit Description: GRADING:19526CY CUT & 2915CY FILL
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/05/2005 | NPPO PRE PERMIT INSPECTION | ACONNOR | Approved | |
08/03/2005 | ENGINEERING PRE-CONSTRUCTION | JBRUCKME | Approved | |
08/05/2005 | STORMWATER INSTALL OF CONTROLS | JBRUCKME | Approved | |
12/28/2005 | STORMWATER FOLLOW-UP INSP | JBRUCKME | Approved | NO STORMWATER CONCERNS |
08/22/2006 | GRADING - INTERMEDIATE | JBRUCKME | Approved | 1. COMPLETE ALL SITE WORK 2. PROVIDE A LETTER OF CERTIFICATION FROM THE ARIZONA REGISTERED P.E. OF RECORD, THAT CERTIFIES TAHT THE PROJECT, RETENTION/DETENTION BASIN AND DRAINAGE WAS CONSTRUCTED IN CONFORMANCE WITH THE APPROVED PLAN AND WILL FUNCTION AS DESIGNED. 3. PROVIDE 24' PAAL OR SUBMIT REVISED PLANS TO C.O.T. ENGINEERING FOR REVIEW AND APPROVAL. 4. COMPLETE ALL SOIL AND SLOPE STABILIZATION. 5. CALL IN FINAL GRADING INSPECTION #09190 FOR TO4BU02490. |
09/08/2006 | GRADING - FINAL | JBRUCKME | Approved | 1. CONSTRUCT PER APPROVED PLAN OR SUBMIT REVISED GRADING AND DEVELOPMENT PLANS TO THE C.O.T. ENGINEERING AND ZONING DIVISIONS FOR REVIEW AND APPROVAL OF ALL MODIFICATIONS. 2. PROVIDE A LETTER OF CERTIFICATION FROM AN ARIZONA REGISTERED P.E. THAT CERTIFIES THAT THE PROJECT AND ALL DRAINAGE AND RETENTION/DETENTION BASINS ARE CONSTRUCTED IN ACCORDANCE WITH THE APPROVED PLANS AND WILL FUNCTION AS DESIGNED. 3. COMPLETE ALL SITE WORK, SOIL AND SLOPE STABILIZATION. 4. PROVIDE 24' PAAL BETWEEN TEP TRANSFORMER AND FIRE HYDRANT EAST OF BUILDING, AND BETWEEN PARKING SPACE AND TRASH ENCLOSURE AT THE SOUTHEAST CORNER OF THE SITE. 5. CONSTRUCT THE WH BASINS TO SPECIFICATIONS SHOWN ON THE GRADING PLAN AND ADDRESS PONDING WATER. 6. PROVIDE STOP SIGNS AND TRAFFIC DIRECTIONAL ARROWS ON THE ASPHALT. SEE NOTES 12 AND 29. 7. REMOVE AND REPLACE ROCK RIP RAP ON SW CORNER OF SITE. SEE NOTE 30. 8. PROVIDE BARRICADE RAILING AND GROUTED ROCK RIP RAP ON SOUTH PERIMETER AS SHOWN ON DETAILS K, I, AND J. 9. CORRECT DETAILS E AND F. 10. PROVIDE TRUNCATED DOMES ON DETAILS AND AT NE AND SE SIDEWALK RAMPS. 11. PROVIDE 5' LANDSCAPE BUFFER/BENCH AT EAST PERIMETER. SEE DETAIL F AND G. 12. PATCH DAMAGED CURBS AND ASPHALT. 13. ADDRESS ALL DRAINAGE EROSION DAMAGE. THIS IS NOT TO BE CONSIDERED A FINAL PUNCH LIST DUE TO INCOMPLETE SITE WORK, |
12/11/2006 | STORMWATER FINAL INSPECTION | JBRUCKME | Approved | |
02/04/2008 | LANDSCAPE INSPECTION | ACONNOR | Approved |