Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address:
3175 N SWAN RD
Apply Date:
03/17/2004
Applicant:
STEVEN GREGOR-EEC ASK FOR BOB
Description:
GRADING:80CY CUT & 8845CY FILL T05BU00623 R- Minor revision to the NE portion of the property - 08/04/05 - PM.
Contractors:
  • RIO WEST DEVELOPMENT AND CONSTRU

Permit Reviews

Permit Number - T04BU00623
Permit Status: Final
Permit Description: GRADING:80CY CUT & 8845CY FILL T05BU00623 R- Minor revision to the NE portion of the property - 08/04/05 - PM.
Start Date Submittal Complete Date Status  
02/17/2005 REVISION - GRADING 02/17/2005 COMPLETED Review Details
03/17/2004 PLANS OK TO SUBMIT - GRADING 03/17/2004 COMPLETED Review Details
03/17/2004 GRADING 04/13/2004 COMPLETED Review Details
04/16/2004 RESUBMITTAL - GRADING ALL 05/05/2004 COMPLETED Review Details
05/12/2004 RESUBMITTAL - GRADING 06/16/2004 COMPLETED Review Details
06/27/2007 REVISION - GRADING 09/19/2007 COMPLETED Review Details
08/04/2005 REVISION - GRADING 08/23/2005 COMPLETED Review Details
09/19/2007 REVISION - GRADING 09/19/2007 COMPLETED Review Details
12/14/2006 REVISION - GRADING 01/24/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04BU00623
Permit Status: Final
Permit Description: GRADING:80CY CUT & 8845CY FILL T05BU00623 R- Minor revision to the NE portion of the property - 08/04/05 - PM.
Total Outstanding Activity Conditions - 1
Date Name
03/17/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04BU00623
Permit Description: GRADING:80CY CUT & 8845CY FILL T05BU00623 R- Minor revision to the NE portion of the property - 08/04/05 - PM.
Total Completed Inspections - 7
Date Description Inspector Results Comments
08/23/2004 NPPO PRE PERMIT INSPECTION ACONNOR Approved
09/20/2005 ENGINEERING PRE-CONSTRUCTION JBRUCKME Approved 1. REPAIR OR REPLACE SILT FENCE ON PERIMETER WHERE NEEDED.
2. CONTROL DUST ON SITE AT ALL TIMES.
3. PROVIDE ADDITIONAL ROCK AT STABILIZED CONSTRUCTION ENTRANCE
4. RE-ESTABLISH A DESIGNATED CONCRETE WASH-OUT AREA.
09/27/2005 STORMWATER INSTALL OF CONTROLS JBRUCKME Approved
11/10/2005 GRADING - FINAL JBRUCKME Approved COMPLETE ALL SITE WORK
THE FOLLOWING PUNCHLIST IS ONLY FOR TEMPORARY C OF O FOR WESTERN PORTION OF THE SITE AND T04CM04772
1. COMPLETE DEPRESSED CURB AT NW CORNER OF SITE.
2. BARRICADE ALL AREAS WHERE ON-GOING CONSTRUCTION ACTIVITY IS OCCURRING TO PREVENT PEDESTRIAN/PUBLIC ACCESS.
3. COMPLETE ROCK RIP RAP IN DRAINAGE AREAS.
4. CONSTRUCT DRAINAGE SWALE AND (5) CURB OPENINGS AT THE SOUTH PERIMETER.
5. DEPRESS LANDSCAPE AREAS MAX. 6" FOR STORMWATER HARVESTING. (SEE GRADING PLAN NOTE #13)
6. PROVIDE A LETTER OF CERTIFICATION FROM ARIZONA REGISTERED P.E. STATING THAT THE DRAINAGE WAY HAS BEEN CONSTRUCTED IN ACCORDANCE WITH THE APPROVED PLANS. SEE GRADING PLAN NOTE#12.C. AND CHAPTER XIV SEC. 14.2(7).
11/10/2005 STORMWATER FOLLOW-UP INSP JBRUCKME Approved 1. REPAIR OR REPLACE SILT FENCING AT PERIMETER OF SITE WHERE NO STABILIZATION HAS BEEN COMPLETED.
2. PROVIDE SWPPP CONTROLS AT THE PERIMETER OF THE UNFINISHED LOTS AT THE EASTERN PORTION OF THE SITE.

3. PROVIDE DUST CONTROL FOR THE EASTERN PORTION TO THIS SITE.
4. SWEEP ALL SEDIMENT AND SOIL FROM THE PUBLIC RIGHT OF WAY AND THE NEW ON-SITE ASPHALT PAVING.
5. UPDATE THE SWPPP TO SHOW CURRENT CONDITIONS.
10/12/2007 LANDSCAPE INSPECTION ACONNOR Approved
10/12/2007 STORMWATER FINAL INSPECTION JBRUCKME Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
BONDRELEASE.TIF DOCUMENTS VIEW
BONDRELEASE2.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
APPROVED_001.TIF GRADING PLANS VIEW
APPROVED_002.TIF GRADING PLANS VIEW
APPROVED_003.TIF GRADING PLANS VIEW
APPROVED_004.TIF GRADING PLANS VIEW
APPROVED_005.TIF GRADING PLANS VIEW