Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM05371
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
1460 W SAINT MARYS RD #01
Address NEW:
1460 W SAINT MARYS RD #01
Apply Date:
11/12/2003
Applicant:
SALSA HOMES L L C ,
Description:
SFR:TD#15-91-47
Contractors:
- SALSA HOMES L L C ,
Permit Reviews
Permit Number - T03CM05371
Permit Status: Final
Permit Description: SFR:TD#15-91-47
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/27/2004 | REVISION | 02/27/2004 | COMPLETED |
| 11/12/2003 | RESIDENTIAL BLDG/ENGINE/WALK THRU | 11/13/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM05371
Permit Status: Final
Permit Description: SFR:TD#15-91-47
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/12/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM05371
Permit Description: SFR:TD#15-91-47
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*/ 1) ABS DWV UNDERGROUND OK. WTR TEST ONE RISER TO TEN FEET OK. 2) OK TO COVER. |
| 12/22/2003 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/22/2003 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/22/2003 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* EXCLUDES PORCHES |
| 01/12/2004 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000*/ CORRECTIONS MADE OK. 2) OK TO COVER. |
| 01/30/2004 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 01/30/2004 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/24/2004 | FRAMING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 02/25/2004 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 02/26/04AM |
| 02/25/2004 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000*/ 1) OK TO CLEAR 2) SENT TO TEP ON 02/26/04AM |
| 02/25/2004 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 03/02/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 03/02/2004 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 03/02/2004 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*/ 1) ABS DWV THRU ROOF OK. 2) PEX OK. 3) CLOSET FLANGES OK. 4) WASTE AND OVERFLOWS OK. 5) OK TO COVER ALL AREAS. |
| 03/17/2004 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | TEP CLEARANCE - PM | JKOZUCH | Approved | |
| 04/28/2004 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :*/ 1) A TRAP ARM MAY NOT CHANGE SIZE. THE TRAP IS TO BE THE SAME SIZE AS THE TRAP ARM. A TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREE WITHOUT ADDING A CLEANOUT. REVIEW CHAPTER 10-TRAPS 94 UPC. REINSPECTED: PLUMBING FINAL OK 2) OK FOR C OF O PENDING ANY OTHER INSPECTION |
| 04/28/2004 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection :* |
| 04/30/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 05/01/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 05/01/2004 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection :* |
| 05/05/2004 | PERMIT FINALED | AMATHIES | Approved |