Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T03CM05371
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2004 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection 0000*/ CORRECTIONS MADE OK. 2) OK TO COVER. | |
| 01/09/2004 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000* | |
| 01/08/2004 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*/ 1) NO PORTION OF ANY WORK MAY BE CONCEALED UNTIL IT HAS BEEN INSPECTED AND APPROVED 2) IT IS YOUR RESPONSIBILITY TO MAKE SURE THE WORK IS READY BEFORE CALLING INSPECTION 3) BACK PITCHED PIPE IS NOT ACCEPTABLE 4) CONTRACTOR TO PAY RE-INSPECTION FEE | |
| 01/07/2004 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*/ 1) CONTRACTOR TO INSURE AT LEAST 12" OF COVER BY FINAL. 2) BACKPITCHED ABS NOT APPROVED. | |
| 01/06/2004 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*/ 1) ABS REQUIRES 2% GRADE - BACKPITCH NOT ACCEPTABLE. 2) EXTERIOR GRADE WILL BE 8" LOWER THAN FINISED FLOOR ABS REQUIRES MIN. 12" OF COVER. |