Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
10/15/2003
Applicant:
U S HOME OF ARIZONA *P
Description:
SFR:TD#15-37-11
Contractors:
  • U S HOME OF ARIZONA *P

Permit Reviews

Permit Number - T03CM04959
Permit Status: C of o
Permit Description: SFR:TD#15-37-11
Start Date Submittal Complete Date Status  
01/29/2004 REVISION 02/25/2004 COMPLETED Review Details
10/15/2003 RESIDENTIAL BLDG/ENGINE/WALK THRU 10/15/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM04959
Permit Status: C of o
Permit Description: SFR:TD#15-37-11
Total Outstanding Activity Conditions - 1
Date Name
10/15/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM04959
Permit Description: SFR:TD#15-37-11
Total Completed Inspections - 23
Date Description Inspector Results Comments
10/23/2003 PLUMBING - SEWER HCS CONNECT JRIVA Approved IVRS - Inspection 0000*
10/23/2003 PLUMBING - YARD WTR LINE/TEST JRIVA Approved IVRS - Inspection 0000*
10/23/2003 PLUMBING - ROUGH, SOIL JRIVA Approved IVRS - Inspection 0000*/ 1) PLUMBING IS NOT PER PLAN 2) CLEANOUT REQUIRED ON MASTER LAV
10/27/2003 ELECTRIC - UFER JRIVA Approved IVRS - Inspection 0000*
10/27/2003 BUILDING PRE-SLAB JRIVA Approved IVRS - Inspection 0000*
10/27/2003 EXCAVATION/LAYOUT REBAR & ZON JRIVA Approved IVRS - Inspection 0000*
11/26/2003 ROOF NAILING JRIVA Approved IVRS - Inspection 0000*
11/26/2003 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0999*/ 1) 4/A8A NOT COMPLIED WITH 2) X BRACES 3 TRUSSES AT EACH GABLE END MISSING IN FRONT 3) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 4) PROVIDE A COMPLETE AND PROPERLY ORGANIZED APPROVED PLAN 5) GABLE END TRUSS AT HOUSE NOT CLIPPED
12/30/2003 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*
12/30/2003 PLUMBING - GAS PRESSURE TEST JRIVA Approved IVRS - Inspection 0000*
12/30/2003 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*
12/30/2003 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*
12/30/2003 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection 0000*
12/30/2003 STUCCO MESH JRIVA Approved IVRS - Inspection 0999*
12/30/2003 FRAMING JRIVA Approved IVRS - Inspection 0999*/ 1) NO DWV WATER TEST PER UPC 712.2 2) 3 PT BEARING TRUSSES NOT BEARING MID POINT 3) 8 90 DEGREE BENDS IN A/C CONDENSATE NO MORE THAN 2-90 DEGREE BENDS ALLOWED. COMPLY OR PROVIDE ENGINEERS APPROVED DESIGN 4) WIRES TRAPPED AT FIRE BLOCK 5) NAIL PROTECT WIRES WITHING 1 1/4" OF STUD SURFACE 6) SEAL VAPOR BARRIER PENETRATIONS 7) TIE INTERIOR BEARING WALL TO EXTERIOR WALLS 8) CUT OVERSIZE TRUSS SHIMS 9) FIRE STOP MINIMUM 1" 2-LAYERS 1/2" 10) NO POTABLE TEST
01/23/2004 ELECTRIC - TEMPORARY SERVICE HCAMPBEL Approved IVRS - Inspection 0000*SENT TO TEP ON 01/26/04AM
01/23/2004 ELECTRIC - CABLE DROP HCAMPBEL Approved IVRS - Inspection 0000*SENT TO TEP ON 01/26/04AM
02/20/2004 SHEET ROCK NAILING JRIVA Approved IVRS - Inspection 0000*
03/17/2004 PERMIT FINALED JRIVA Approved
03/17/2004 MECHANICAL - FINAL JRIVA Approved IVRS - Inspection 0000*
03/17/2004 PLUMBING - FINAL JRIVA Approved IVRS - Inspection 0000*
03/17/2004 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection 0000*
03/17/2004 BUILDING - FINAL JRIVA Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
None CERT OF OCC VIEW