Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Address NEW:
6475 E GOLF LINKS RD
Apply Date:
09/19/2003
Applicant:
N/A
Description:
T02VL00624: KITCHEN UPGRADE BWOP
Contractors:
  • MEHL ELECTRIC SERVICE INC,*C
  • 24-7 PLUMBING

Permit Reviews

Permit Number - T03CM04588
Permit Status: Final
Permit Description: T02VL00624: KITCHEN UPGRADE BWOP
Start Date Submittal Complete Date Status  
01/07/2004 REVISION 01/07/2004 COMPLETED Review Details
09/19/2003 PLANS OK TO SUBMIT - COMM 09/22/2003 COMPLETED Review Details
09/22/2003 OTHER 10/08/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM04588
Permit Status: Final
Permit Description: T02VL00624: KITCHEN UPGRADE BWOP
Total Outstanding Activity Conditions - 1
Date Name
09/19/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03CM04588
Permit Description: T02VL00624: KITCHEN UPGRADE BWOP
Total Completed Inspections - 16
Date Description Inspector Results Comments
10/09/2003 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection 0000*/ 1) PATCH HOLE IN GREASE DUCT WITH 16 GA STEEL. CALL FOR INSPECTION PRIOR TO PATCHING SHAFT
10/09/2003 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*
10/09/2003 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*
10/09/2003 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0999*
10/28/2003 FRAMING RSUBA Approved IVRS - Inspection 0000*/ FRAMING OF UNISEX WALL. SHEET ROCK NAILING OK. NOTES: 1) REMOVE TOILET AT UNISEX BATHROOM THATS NOT INDICATED ON PLANS. 2) PROVIDE HANDICAP HANDLE INTO ADA BATHROOM. 3) WRAP PLUMBING BELOW SINK. 4) PROVIDE ADA APPROVED FAUCET. 5) PROVIDE HC SIGNAGE AT ADA. BATHROOM. 6) RELOCATE TOWEL DISPENSOR TO ADA. 7) EX. FAN IN KITCHEN NEEDS TO BE INTERLOCKED WITH MAKE UP AIR. 8) KEEP ALL REQUIRED EXITS FROM BEING OBSTRUCTED. 9) PER MECH. INSPECTOR REMOVE EX. FAN FOR INSPECTION OF GREASE DUCT AND SHAFT. 10) WTR HTR IN DRESSING RM DOES NOT HAVE FLU VENT CONNECTED. 11) T& P VALVE NOT WORKING (REMOVE FLEX LINE) 12) MUST CLEAN UP DEBRIS IN WTR HTR RM. 13) FILLER BLANKS OPEN AT SERIAL PANEL. 14) IMPROPER T&P OFF OF 200 AMP DISCONNECT SWITCH AT MAIN SERVICE. 15) PROVIDE VENTILATION AT WTR HTR (DRESSING ROOM). 16) CLEAN UP ALL EXTENSION CORD WIRING (REMOVE WHERE NOT ALLOWED BY CODE) 17) EXPOSED SPLICE AT ELEC. CLOSET (DRESSING RM) REMOVE OR PROPERLY JUNCTION. 18) INSTALL COVER AT NEON J-BOX AT UNI-SEX BATHROOM AND REMOVE EXTENSION CORD AT ALL NEON LIGHTS. 19) DEVICE COVER MISSING AT KITCHEN. 20) REMOVE EXPOSED N.M. CABLE AT D.J. BOOTH (RECOMMEND PLUG MOLD TO CLEAN UP D.J. BOOTH.) 21) INSTALL MISSING FIXTURE COVER AT STAIR FIXTURE.
11/14/2003 PLUMBING - FINAL RRICH Approved IVRS - Inspection 0000*/ ALL CORRECTIONS MADE.
11/14/2003 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection 0000*
11/14/2003 PLUMBING - ABOVE CEILING RRICH Approved
11/14/2003 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection 0000*
11/14/2003 PLUMBING - ROUGH, SOIL RRICH Approved
11/19/2003 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*/ REVISION TO ELECTRICAL - FINAL APPROVAL.
11/19/2003 ELECTRIC - INTERMEDIATE JORTA Approved
12/31/2003 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*
12/31/2003 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection 0000*
01/14/2004 BUILDING - FINAL RSUBA Approved IVRS - Inspection 0000*
01/15/2004 PERMIT FINALED RSUBA Approved