Permit: T03CM04588
Permit Details
Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
6475 E GOLF LINKS RD
Address NEW:
6475 E GOLF LINKS RD
Apply Date:
09/19/2003
Applicant:
N/A
Description:
T02VL00624: KITCHEN UPGRADE BWOP
Contractors:
- MEHL ELECTRIC SERVICE INC,*C
- 24-7 PLUMBING
Permit Reviews
Permit Number - T03CM04588
Permit Status: Final
Permit Description: T02VL00624: KITCHEN UPGRADE BWOP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/07/2004 | REVISION | 01/07/2004 | COMPLETED |
| 09/19/2003 | PLANS OK TO SUBMIT - COMM | 09/22/2003 | COMPLETED |
| 09/22/2003 | OTHER | 10/08/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM04588
Permit Status: Final
Permit Description: T02VL00624: KITCHEN UPGRADE BWOP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/19/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM04588
Permit Description: T02VL00624: KITCHEN UPGRADE BWOP
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2003 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection 0000*/ 1) PATCH HOLE IN GREASE DUCT WITH 16 GA STEEL. CALL FOR INSPECTION PRIOR TO PATCHING SHAFT |
| 10/09/2003 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
| 10/09/2003 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
| 10/09/2003 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0999* |
| 10/28/2003 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000*/ FRAMING OF UNISEX WALL. SHEET ROCK NAILING OK. NOTES: 1) REMOVE TOILET AT UNISEX BATHROOM THATS NOT INDICATED ON PLANS. 2) PROVIDE HANDICAP HANDLE INTO ADA BATHROOM. 3) WRAP PLUMBING BELOW SINK. 4) PROVIDE ADA APPROVED FAUCET. 5) PROVIDE HC SIGNAGE AT ADA. BATHROOM. 6) RELOCATE TOWEL DISPENSOR TO ADA. 7) EX. FAN IN KITCHEN NEEDS TO BE INTERLOCKED WITH MAKE UP AIR. 8) KEEP ALL REQUIRED EXITS FROM BEING OBSTRUCTED. 9) PER MECH. INSPECTOR REMOVE EX. FAN FOR INSPECTION OF GREASE DUCT AND SHAFT. 10) WTR HTR IN DRESSING RM DOES NOT HAVE FLU VENT CONNECTED. 11) T& P VALVE NOT WORKING (REMOVE FLEX LINE) 12) MUST CLEAN UP DEBRIS IN WTR HTR RM. 13) FILLER BLANKS OPEN AT SERIAL PANEL. 14) IMPROPER T&P OFF OF 200 AMP DISCONNECT SWITCH AT MAIN SERVICE. 15) PROVIDE VENTILATION AT WTR HTR (DRESSING ROOM). 16) CLEAN UP ALL EXTENSION CORD WIRING (REMOVE WHERE NOT ALLOWED BY CODE) 17) EXPOSED SPLICE AT ELEC. CLOSET (DRESSING RM) REMOVE OR PROPERLY JUNCTION. 18) INSTALL COVER AT NEON J-BOX AT UNI-SEX BATHROOM AND REMOVE EXTENSION CORD AT ALL NEON LIGHTS. 19) DEVICE COVER MISSING AT KITCHEN. 20) REMOVE EXPOSED N.M. CABLE AT D.J. BOOTH (RECOMMEND PLUG MOLD TO CLEAN UP D.J. BOOTH.) 21) INSTALL MISSING FIXTURE COVER AT STAIR FIXTURE. |
| 11/14/2003 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection 0000*/ ALL CORRECTIONS MADE. |
| 11/14/2003 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection 0000* |
| 11/14/2003 | PLUMBING - ABOVE CEILING | RRICH | Approved | |
| 11/14/2003 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection 0000* |
| 11/14/2003 | PLUMBING - ROUGH, SOIL | RRICH | Approved | |
| 11/19/2003 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000*/ REVISION TO ELECTRICAL - FINAL APPROVAL. |
| 11/19/2003 | ELECTRIC - INTERMEDIATE | JORTA | Approved | |
| 12/31/2003 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000* |
| 12/31/2003 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection 0000* |
| 01/14/2004 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
| 01/15/2004 | PERMIT FINALED | RSUBA | Approved |