Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/08/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/28/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ FRAMING OF UNISEX WALL. SHEET ROCK NAILING OK. NOTES: 1) REMOVE TOILET AT UNISEX BATHROOM THATS NOT INDICATED ON PLANS. 2) PROVIDE HANDICAP HANDLE INTO ADA BATHROOM. 3) WRAP PLUMBING BELOW SINK. 4) PROVIDE ADA APPROVED FAUCET. 5) PROVIDE HC SIGNAGE AT ADA. BATHROOM. 6) RELOCATE TOWEL DISPENSOR TO ADA. 7) EX. FAN IN KITCHEN NEEDS TO BE INTERLOCKED WITH MAKE UP AIR. 8) KEEP ALL REQUIRED EXITS FROM BEING OBSTRUCTED. 9) PER MECH. INSPECTOR REMOVE EX. FAN FOR INSPECTION OF GREASE DUCT AND SHAFT. 10) WTR HTR IN DRESSING RM DOES NOT HAVE FLU VENT CONNECTED. 11) T& P VALVE NOT WORKING (REMOVE FLEX LINE) 12) MUST CLEAN UP DEBRIS IN WTR HTR RM. 13) FILLER BLANKS OPEN AT SERIAL PANEL. 14) IMPROPER T&P OFF OF 200 AMP DISCONNECT SWITCH AT MAIN SERVICE. 15) PROVIDE VENTILATION AT WTR HTR (DRESSING ROOM). 16) CLEAN UP ALL EXTENSION CORD WIRING (REMOVE WHERE NOT ALLOWED BY CODE) 17) EXPOSED SPLICE AT ELEC. CLOSET (DRESSING RM) REMOVE OR PROPERLY JUNCTION. 18) INSTALL COVER AT NEON J-BOX AT UNI-SEX BATHROOM AND REMOVE EXTENSION CORD AT ALL NEON LIGHTS. 19) DEVICE COVER MISSING AT KITCHEN. 20) REMOVE EXPOSED N.M. CABLE AT D.J. BOOTH (RECOMMEND PLUG MOLD TO CLEAN UP D.J. BOOTH.) 21) INSTALL MISSING FIXTURE COVER AT STAIR FIXTURE. |
| 10/09/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* NO DETAILS FOR FRAMING AROUND HOOD. 2) PP A1.1 INDICATES WORK TO BE DONE IN UNISEX BUT DOES NOT MENTION HOOD FRAME OUT, WHY?3) FRAMING & SHEETROCK WORK HAVE NOT BEEN DONE ON UNISEX. PLEASE PROVIDE DETAIL OR RE FEE WILL BE APPLIED |