Permit: T03CM04475
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
7255 E BROADWAY BL
Address NEW:
7255 E BROADWAY BL
Apply Date:
09/12/2003
Applicant:
METRO PERMIT EXPRESS, INC
Description:
TI:RETAIL
Contractors:
- DIVISION II CONSTRUCTION COMPANY
Permit Reviews
Permit Number - T03CM04475
Permit Status: C of o
Permit Description: TI:RETAIL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/12/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 09/16/2003 | COMPLETED |
| 09/17/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 09/18/2003 | COMPLETED |
| 10/01/2003 | 3RD PARTY REVIEW-COMMERCIAL | 10/28/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM04475
Permit Status: C of o
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/12/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM04475
Permit Description: TI:RETAIL
Total Completed Inspections - 28
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2003 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 11/24/2003 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*/ MENS, WOMENS, BREAK ROOM, JANITOR ROOM. PLEASE PROVIDE INSULATION AS PLAN. TEST OK. OK TO COVER THIS AREA. |
| 12/10/2003 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) BONDING JUMPERS TO BE AS PER 250.102 AND 250.66 2) OK WALLS ? AND BELOW 3) OK TO CLEAR-CLEAR AS SERVICE UPGRADE. NOTE: BOND IS NOT REQUIRED SERVICE IS EXISTING AND CURRENTLY ENERGIZED-WILL JUST BE UPGRADED |
| 12/10/2003 | SHEET ROCK NAILING | RSUBA | Approved | |
| 12/10/2003 | FRAMING | RSUBA | Approved | |
| 12/15/2003 | ELECTRIC - SERVICE UPGRADE | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK BONDING AT SERVICE |
| 12/24/2003 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK VESTABLE |
| 01/12/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*/ DISCUSSED CONDENSATE DRAIN LINE ON ROOF INSTEAD OF INSIDE BLDG. PROVIDE A REVISION FROM YOUR DESIGNER IF CHANGING YOUR PLANS. INSPECTED SUSPENDED ROUGH DUCT. OK TO PROCEED WITH GRID. |
| 01/20/2004 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*/ 1) OK FOR C OF O |
| 01/20/2004 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | |
| 02/12/2004 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
| 02/12/2004 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 02/12/2004 | FIRE - FINAL | LTHOMAS | Approved | IVRS - Inspection 0000*OK FOR C OF O |
| 02/12/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | IVRS - Inspection 0000* |
| 02/12/2004 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 02/12/2004 | PLUMBING - GAS PRESS TEST FNL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 02/12/2004 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | |
| 02/12/2004 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | |
| 02/12/2004 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 02/13/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 02/18/2004 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK FINAL |
| 02/18/2004 | ELECTRIC - CONSTRUCTION POWER | RHOLLAND | Approved | |
| 02/18/2004 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | |
| 02/24/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 02/24/2004 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
| 02/24/2004 | BUILDING ABOVE CEILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 02/24/2004 | ROOF NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 02/25/2004 | PERMIT FINALED | RSUBA | Approved |