Permit Reviews

Permit Number - T03CM02600
Permit Status: C of o
Permit Description: TI:AUTO REPAIR
Start Date Submittal Complete Date Status  
05/29/2003 COMMERCIAL TI 06/10/2003 COMPLETED Review Details
06/10/2003 OTHER 07/07/2003 COMPLETED Review Details
07/28/2003 RESUBMITTAL 08/25/2003 COMPLETED Review Details
09/03/2003 RESUBMITTAL 09/05/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM02600
Permit Status: C of o
Permit Description: TI:AUTO REPAIR
Total Outstanding Activity Conditions - 1
Date Name
05/29/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM02600
Permit Description: TI:AUTO REPAIR
Total Completed Inspections - 21
Date Description Inspector Results Comments
09/10/2003 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*/ INSPECTED EXHAUST AND SUPPLY DUCTS IN RESTROOMS. EXHAUST FAN IS MISSING THE BACKDRAFT DAMPER. WILL CHECK ON NEXT INSPECTION. PROVIDE A SECONDARY DRAIN ON FAN COIL AND TERMINATE IN A CONSPICUOUS LOCATION. OK FOR SHEET ROCK.
09/10/2003 FRAMING LHANLY Approved IVRS - Inspection 0000*
09/12/2003 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection 0000*
09/12/2003 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection 0000*
09/20/2003 SHEET ROCK NAILING HLEYVA Approved IVRS - Inspection 0000*
10/01/2003 RIGHT OF WAY - FINAL DLEE Approved TEMP ONLY
10/01/2003 SIGN - FINAL JYBARRA Approved
10/01/2003 FIRE - FINAL JEGAN Approved IVRS - Inspection 0000*/ 1) OK FOR C OF O
10/01/2003 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
10/03/2003 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*/ OK FOR C OF O.
10/09/2003 MECHANICAL - PROGRESS CWILLIAM Approved
10/09/2003 MECHANICAL - ABOVE CEILING CWILLIAM Approved
10/09/2003 PLUMBING - FINAL RRICH Approved IVRS - Inspection 0000*/ ALL CORRECTIONS MADE.
10/09/2003 PLUMBING - PROGRESS RRICH Approved
10/09/2003 PLUMBING - ABOVE CEILING RRICH Approved
10/09/2003 ELECTRIC - INTERMEDIATE JORTA Approved
10/09/2003 BUILDING - FINAL LHANLY Approved
10/09/2003 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*
10/09/2003 BUILDING ABOVE CEILING LHANLY Approved
12/03/2003 ENGINEERING - FINAL DROBERTS Approved TEMPORARY C OF O APPROVED AT THIS TIME, FINAL NOT TO BE GIVEN UNTIL THE WESTERN PARKING LOT IS COMPLETED PER THE APPROVED PLANS. CONTACT CRAIG GROSS AND MATT FLICK TO ADDRESS THE REMAINING ITEMS.
09/16/2004 PERMIT FINALED LLESNY Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_09-16-2004.TIF CERT OF OCC VIEW
TEMP C OF O_04-20-2004.TIF CERT OF OCC VIEW