Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T03CM02600
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2003 | ELECTRIC - INTERMEDIATE | Approved | ||
| 09/17/2003 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) ROUGH-IN OF FRAMED WALLS-APPROVED | |
| 09/12/2003 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0245$/ 1) TAPING OF MC CABLE DOES NOT SOLVE PROBLEM OF INDIVIDUALIZED WIRES SQUEEZED IN MC CONNECTOR 2) LOOSE CONNECTOR STILL 3) TOO SHARP OF MC CABLE BENDING RADIUS 4) NEED LETTER ON MC 5) A REFEE IS DUE BEFORE THE NEXT INSPECTION | |
| 09/10/2003 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) RECEPT MINIMUM HEIGHT REQUIRED IS 18" 2) NEED WIRING IN STUD TO BE IN CENTER OF 2 X 4 OR USE WIRE PROTECTION 3) MC.C CABLE NOT INSERTED INTO CONNECTOR ALL THE WAY 4) NEED PROPER CRIMP SLEEVE FOR COMBINING EQUIPMENT GROUND 5) WRAP GROUND WIRE INTO GROUND SCREW CORRECTLY 6) NEED ? SEALS 7) NEED TO COLOR CODE CONDUCTOR WITH APPROPRIATE ELECTRICAL COLOR 8) NEED LETTER FROM ENGINEER ALLOWING THE USE OF M.C. CABLE, INCLUDE ACT. NO. ADRESS ETC... |