Permit: T03CM01126
Permit Details
Apply Date:
03/05/2003
Applicant:
MURATORE STACY
Description:
ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Permit Reviews
Permit Number - T03CM01126
Permit Status: Expired
Permit Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2004 | REVISION | 01/30/2004 | COMPLETED |
| 03/05/2003 | PLANS OK TO SUBMIT - RES | 03/05/2003 | COMPLETED |
| 03/05/2003 | RESIDENTIAL BLDG/ZONING/FLOOD | 04/03/2003 | COMPLETED |
| 06/04/2003 | RESUBMITTAL | 06/19/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM01126
Permit Status: Expired
Permit Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/05/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03CM01126
Permite Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2004 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection :HANDRAK MUST TERMINATE INTO WALL OR AT SAFTEY TERMINAL KITCHEN ISLAND MUST HAVE GFI OUTLET SHEET METAL SCREWS NO PERMITTED IN ELEC PANEL DEAD FRONT A/C DISCONNECTS BEHIND UNITS NOT PERMITTED HOSE BIBBS REQUIRE ANTI-SYPHON DEVICE |
| 07/26/2004 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/26/2004 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/26/2004 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T03CM01126
Permit Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2003 | EXCAVATION/LAYOUT REBAR & ZON | MTESTER | Approved | IVRS - Inspection 0000* |
| 08/01/2003 | STEM WALL/RETAINING WALL | DQUINN | Approved | IVRS - Inspection 0000* |
| 08/15/2003 | PLUMBING - ROUGH, SOIL | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 08/18/2003 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 09/15/2003 | ELECTRIC - TEMPORARY SERVICE | BSTEVENS | Approved | SENT TO TEP 09/16/2003 9:15A.M. |
| 09/15/2003 | ELECTRIC - CABLE DROP | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 09/15/2003 | ELECTRIC - SERVICE RELOCATION | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 10/17/2003 | REINFORCED MASONRY PRE-GROUT | BSTEVENS | Approved | IVRS - Inspection 0000*/ 3 COURSES MASONRY ON TOP OF ADOBE OK TO GROUT. |
| 11/18/2003 | FRAMING | EDURAZO | Approved | IVRS - Inspection 0999*/ 1) COMPLETE ALL TRADES, ELECTRIC, PLUMBING AND MECHANICAL PRIOR TO FRAME INSPECTION |
| 12/17/2003 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0999*/ 1) COVERED WITHOUT INSPECTION, EXPOSE |
| 12/19/2003 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0999*/ 1) MECHANICAL REGISTERS MUST BE SUPPORTED ON AT LEAST 3 SIDES 2) SECURE FLEX DUCT ABOVE CEILING LEVEL |
| 12/19/2003 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 12/23/2003 | EXT METAL CLIPS/EXT SHEATHING | FGREER | Approved | IVRS - Inspection 0999*/ 1) SHEATHING LOOSE THRU-OUT 2) NAIL MISSING AT SHEATHING |
| 02/04/2004 | PLUMBING - GAS PRESSURE TEST | FGREER | Approved | IVRS - Inspection 0000* |
| 02/04/2004 | PLUMBING - INTERMEDIATE | FGREER | Approved | IVRS - Inspection 0000*/ 1) FRAMING NOT COMPLETE |
| 04/01/2004 | SHEET ROCK NAILING | FGREER | Approved | IVRS - Inspection 0000* |
| 04/01/2004 | U VALUE FOR WINDOW | FGREER | Approved | IVRS - Inspection 0000* |
| 04/01/2004 | STUCCO MESH | FGREER | Approved | IVRS - Inspection 0000* |
| 05/18/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | |
| 05/25/2004 | PLUMBING - SEWER HCS CONNECT | ROHAVER | Approved | IVRS - Inspection :* |
| 05/25/2004 | PLUMBING - YARD WTR LINE/TEST | ROHAVER | Approved | IVRS - Inspection :* |
| 06/14/2004 | ELECTRIC - SERVICE UPGRADE | JRIVA | Approved | IVRS - Inspection :* |
| 06/14/2004 | ELECTRIC - UNDERGROUND | JRIVA | Approved | IVRS - Inspection :* |
| 06/14/2004 | ELECTRIC - UFER | JRIVA | Approved | IVRS - Inspection :* |
| 07/27/2004 | PLUMBING - GAS PRESS TEST FNL | BSTEVENS | Approved | IVRS - Inspection :* |