Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
2901 E ADAMS ST
Address NEW:
2901 E ADAMS ST
Apply Date:
03/05/2003
Applicant:
MURATORE STACY
Description:
ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS

Permit Reviews

Permit Number - T03CM01126
Permit Status: Expired
Permit Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Start Date Submittal Complete Date Status  
01/30/2004 REVISION 01/30/2004 COMPLETED Review Details
03/05/2003 PLANS OK TO SUBMIT - RES 03/05/2003 COMPLETED Review Details
03/05/2003 RESIDENTIAL BLDG/ZONING/FLOOD 04/03/2003 COMPLETED Review Details
06/04/2003 RESUBMITTAL 06/19/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM01126
Permit Status: Expired
Permit Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Total Outstanding Activity Conditions - 1
Date Name
03/05/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03CM01126
Permite Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
07/26/2004 BUILDING - FINAL N/A Denied IVRS - Inspection :HANDRAK MUST TERMINATE INTO WALL OR AT SAFTEY TERMINAL
KITCHEN ISLAND MUST HAVE GFI OUTLET
SHEET METAL SCREWS NO PERMITTED IN ELEC PANEL DEAD FRONT
A/C DISCONNECTS BEHIND UNITS NOT PERMITTED
HOSE BIBBS REQUIRE ANTI-SYPHON DEVICE
07/26/2004 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/26/2004 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/26/2004 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Completed Inspections

Permit Status: Expired
Permit Number: T03CM01126
Permit Description: ADDITION:GREAT ROOM/KITCHEN/LIBRARY/BEDROOMS/BATHS
Total Completed Inspections - 25
Date Description Inspector Results Comments
07/25/2003 EXCAVATION/LAYOUT REBAR & ZON MTESTER Approved IVRS - Inspection 0000*
08/01/2003 STEM WALL/RETAINING WALL DQUINN Approved IVRS - Inspection 0000*
08/15/2003 PLUMBING - ROUGH, SOIL BSTEVENS Approved IVRS - Inspection 0000*
08/18/2003 BUILDING PRE-SLAB BSTEVENS Approved IVRS - Inspection 0000*
09/15/2003 ELECTRIC - TEMPORARY SERVICE BSTEVENS Approved SENT TO TEP 09/16/2003 9:15A.M.
09/15/2003 ELECTRIC - CABLE DROP BSTEVENS Approved IVRS - Inspection 0000*
09/15/2003 ELECTRIC - SERVICE RELOCATION BSTEVENS Approved IVRS - Inspection 0000*
10/17/2003 REINFORCED MASONRY PRE-GROUT BSTEVENS Approved IVRS - Inspection 0000*/ 3 COURSES MASONRY ON TOP OF ADOBE OK TO GROUT.
11/18/2003 FRAMING EDURAZO Approved IVRS - Inspection 0999*/ 1) COMPLETE ALL TRADES, ELECTRIC, PLUMBING AND MECHANICAL PRIOR TO FRAME INSPECTION
12/17/2003 ROOF NAILING JRIVA Approved IVRS - Inspection 0999*/ 1) COVERED WITHOUT INSPECTION, EXPOSE
12/19/2003 MECHANICAL - INTERMEDIATE BSTEVENS Approved IVRS - Inspection 0999*/ 1) MECHANICAL REGISTERS MUST BE SUPPORTED ON AT LEAST 3 SIDES 2) SECURE FLEX DUCT ABOVE CEILING LEVEL
12/19/2003 ELECTRIC - INTERMEDIATE BSTEVENS Approved IVRS - Inspection 0000*
12/23/2003 EXT METAL CLIPS/EXT SHEATHING FGREER Approved IVRS - Inspection 0999*/ 1) SHEATHING LOOSE THRU-OUT 2) NAIL MISSING AT SHEATHING
02/04/2004 PLUMBING - GAS PRESSURE TEST FGREER Approved IVRS - Inspection 0000*
02/04/2004 PLUMBING - INTERMEDIATE FGREER Approved IVRS - Inspection 0000*/ 1) FRAMING NOT COMPLETE
04/01/2004 SHEET ROCK NAILING FGREER Approved IVRS - Inspection 0000*
04/01/2004 U VALUE FOR WINDOW FGREER Approved IVRS - Inspection 0000*
04/01/2004 STUCCO MESH FGREER Approved IVRS - Inspection 0000*
05/18/2004 TEP CLEARANCE - AM JKOZUCH Approved
05/25/2004 PLUMBING - SEWER HCS CONNECT ROHAVER Approved IVRS - Inspection :*
05/25/2004 PLUMBING - YARD WTR LINE/TEST ROHAVER Approved IVRS - Inspection :*
06/14/2004 ELECTRIC - SERVICE UPGRADE JRIVA Approved IVRS - Inspection :*
06/14/2004 ELECTRIC - UNDERGROUND JRIVA Approved IVRS - Inspection :*
06/14/2004 ELECTRIC - UFER JRIVA Approved IVRS - Inspection :*
07/27/2004 PLUMBING - GAS PRESS TEST FNL BSTEVENS Approved IVRS - Inspection :*

Documents