Inspection History Details
Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SOUTH AND NORTH EXT. OUTLET NOT GFI AND NEEDS BUBBLE COVERS 2) A/C DISCONNECTS ARE OVER FUSED 3) CUT CLEANOUTS ON N.E. PORCH TO BE FLUSH WITH SLAB 4) CUT POSTS OFF CONCRETE AT S.E. PORCH 5) GROUNDS AND NEUTRALS MUST BE SAME GAUGE UNDER SCREW (2 MAX) 6) TRAP CONDENSATES AND DISCONNECT H20 HEATER PAN FROM CONDENSATE DRAIN 7) NEED SECONDARY CONDENSATE DRAINS 8) ROOF OUTLETS NOT GFI PROTECTED 9) SMOKIES INOPERABLE 10) NEED HANDRAILS TO RETURN TO WALL 11) CLAMP OPEN FIREPLACE DAMPER 12) RAISE DISHWASHER DRAIN LINE TO COUNTER BOTTOM 13) PROTECT EXPOSED WIRING IN SHOP AND GFI PROTECT |
|
| 07/26/2004 | BUILDING - FINAL | Denied | IVRS - Inspection :HANDRAK MUST TERMINATE INTO WALL OR AT SAFTEY TERMINAL KITCHEN ISLAND MUST HAVE GFI OUTLET SHEET METAL SCREWS NO PERMITTED IN ELEC PANEL DEAD FRONT A/C DISCONNECTS BEHIND UNITS NOT PERMITTED HOSE BIBBS REQUIRE ANTI-SYPHON DEVICE |