Permit: T03CM00544
Permit Details
Apply Date:
02/04/2003
Applicant:
RON DECKER
Description:
NEW:WAREHOUSE
Architects:
- LEE, LYO TERRELL
Contractors:
- D R I PARTNERS INC
Permit Reviews
Permit Number - T03CM00544
Permit Status: C of o
Permit Description: NEW:WAREHOUSE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/04/2003 | PLANS OK TO SUBMIT - COMM | 03/12/2003 | COMPLETED |
03/12/2003 | 3RD PARTY REVIEW-COMMERCIAL | 03/17/2003 | COMPLETED |
03/18/2003 | RESUBMITTAL | 03/24/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM00544
Permit Status: C of o
Permit Description: NEW:WAREHOUSE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/04/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM00544
Permit Description: NEW:WAREHOUSE
Total Completed Inspections - 37
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2003 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) NOTE: BLDG DRAIN IS STUBBED OUT @ TWO WAY C.O. ONLY. 3.) OK TO BACKFILL TRENCH. |
04/12/2003 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*SOIL WATER TEST IS OK. 2.) OK TO BACKFILL TRENCH. |
05/14/2003 | ELECTRIC - UFER | LHANLY | Approved | IVRS - Inspection 0000*#4/0 STRANDED WIRE COUPLED TO 20' REBAR IN BOTTOM 1/3 OF FOOTING. PLAN CALLS FOR 3/0. |
06/04/2003 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
06/09/2003 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
06/13/2003 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
06/20/2003 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection 0000*/ 1) SECONDARY CONDUITS 4" EACH APPROVED A AND B |
06/20/2003 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
06/20/2003 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
06/26/2003 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) YARD WATER LINE FROM METER TO BLDG SERVICE IS OK 2) OK TO BACKFILL TRENCH |
07/01/2003 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
07/09/2003 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
07/28/2003 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*/ 1) OK FOR CEILING TILES |
07/28/2003 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) OK FOR GRID AND TILE. |
07/28/2003 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
07/29/2003 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000* |
08/01/2003 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000*/ 1) NOTE: ALREADY ? |
08/05/2003 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000*/ S.T.O.I. |
08/05/2003 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000*SENT TO TEP ON 08/07PM |
08/06/2003 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*/ OK FOR C OF O. |
08/07/2003 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
08/07/2003 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | |
08/07/2003 | ELECTRIC - INTERMEDIATE | JORTA | Approved | |
08/12/2003 | RIGHT OF WAY - FINAL | DLEE | Approved | |
08/12/2003 | NPPO - FINAL | PGILBERT | Approved | |
08/12/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000$ |
08/12/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | |
08/12/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
08/12/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
08/12/2003 | FIRE SPKLR - OH PIPING & HYDRO | JEGAN | Approved | IVRS - Inspection 0000* |
08/12/2003 | FIRE SPKLR - UG PIPING FLUSH | JEGAN | Approved | IVRS - Inspection 0000* |
08/12/2003 | FIRE SPKLR - UG, PIPING, HYDRO | JEGAN | Approved | IVRS - Inspection 0000* |
08/14/2003 | PERMIT FINALED | lhanly | Approved | |
08/14/2003 | ENGINEERING - FINAL | DROBERTS | Approved | |
08/14/2003 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |
08/15/2003 | OUTDOOR LIGHTING FINAL | JORTA | Approved | |
08/15/2003 | ELECTRIC - TEMPORARY SERVICE | JORTA | Approved |