Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Address NEW:
9136 E VALENCIA RD
Apply Date:
01/22/2003
Applicant:
N/A
Description:
NEW:RETAIL SHELL
Architects:
  • REED, KURT DOUGLAS
Contractors:
  • BARCLAY GROUP CONSTRUCTION SERVICES L L C

Permit Reviews

Permit Number - T03CM00269
Permit Status: Final
Permit Description: NEW:RETAIL SHELL
Start Date Submittal Complete Date Status  
01/22/2003 3RD PARTY REVIEW-COMMERCIAL 03/19/2003 COMPLETED Review Details
03/18/2003 SITE 04/25/2003 COMPLETED Review Details
03/19/2003 RESUBMITTAL 04/25/2003 COMPLETED Review Details
05/28/2003 3RD PARTY REVIEW-REVISION/OTHER 06/23/2003 COMPLETED Review Details
08/26/2003 3RD PARTY REVIEW-REVISION/OTHER 08/29/2003 COMPLETED Review Details
09/12/2003 3RD PARTY REVIEW-REVISION/OTHER 10/06/2003 COMPLETED Review Details
09/17/2003 3RD PARTY REVIEW-REVISION/OTHER 10/06/2003 COMPLETED Review Details
10/02/2003 3RD PARTY REVIEW-REVISION/OTHER 10/13/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM00269
Permit Status: Final
Permit Description: NEW:RETAIL SHELL
Total Outstanding Activity Conditions - 1
Date Name
01/22/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03CM00269
Permit Description: NEW:RETAIL SHELL
Total Completed Inspections - 43
Date Description Inspector Results Comments
06/17/2003 ELECTRIC - UFER JORTA Approved #4, #2 SOL. CU. UFER ATTACHED TO 20' RBR.
06/19/2003 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection 0000* 1) AS COLUMNS GO UP YOU WILL NEED TO KEEP VERTICALS FULL CONSTRAINED IN TIES. 2) VERTICALS @ 2 FRONT COLS. WILL REQUIRE 30"LAP SPLICE
06/25/2003 PLUMBING - ROUGH, SOIL TRINIVJR Approved 1) SOIL WATER TEST IS OK 2) OK TO BACKFILL TRENCH
07/01/2003 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*
07/11/2003 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection 0000*
07/22/2003 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection 0000*/ HCS CONNECTION IS OK. 2) SOIL WATER TEST IS OK. 3) OK TO BACKFILL TRENCH.
07/28/2003 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*
08/07/2003 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
08/20/2003 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*/ 1) OVERHEAD WATER DISTRIBUTION IS OK. 2) SOIL WATER TEST IS OK. 3) ISOLATED C.W. SHUT OFF VALVES OK. 4) OK FOR DRYWALL. 5) NOTE: WILL REQUIRE A LETTER FROM ARCHITECT STATING THAT SUITE C-2, 1" OVERHEAD WATER FOR FUTURE EQUIPMENT IS NOT NEEDED AT THIS TIME.
08/20/2003 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
08/26/2003 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
08/27/2003 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
08/27/2003 STUCCO MESH LHANLY Approved IVRS - Inspection 0000*
08/27/2003 FRAMING LHANLY Approved IVRS - Inspection 0000*
09/12/2003 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000/ PLANS SHOW DUCT SMOKE DETECTORS. PROVIDE REVISION IF DELETING DETECTORS. INSULATE ROUND SHEET METAL DUCT AND SEAL JOINTS. PROVIDE THERMOSTATS IN LOCATIONS AS PER PLANS. WILL CHECK CORRECTIONS ON FINAL INSPECTION. OK FOR CEILING TILES. DUCT SMOKE DETECTORS NOT REQUIRED BY CODE FOR THIS APPLICATION.
09/12/2003 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*
09/12/2003 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection 0000*
09/12/2003 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
09/12/2003 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection 0000*
09/12/2003 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection 0000*
09/16/2003 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection 0000*
09/17/2003 ELECTRIC - ABOVE CEILING RMAJUTA Approved IVRS - Inspection 0000*
09/17/2003 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection 0000*
09/17/2003 ELECTRIC - UNDERGROUND RMAJUTA Approved IVRS - Inspection 0000*
09/23/2003 MECHANICAL - TEMP PWR FOR TEST JMILITEL Approved
09/23/2003 PLUMBING - TEMP POWER FOR TEST RRICH Approved
09/23/2003 ELECTRIC - TEMP POWER FOR TEST JORTA Approved
09/23/2003 ELECTRIC - CABLE DROP JORTA Approved IVRS - Inspection 0000*/ 1) NEEDS BOND POSTED 2) TEMP POWER FOR HOUSE PANEL (TEST) SENT TO TEP ON 0926AM
09/23/2003 BUILDING - TEMP POWER FOR TEST LHANLY Approved
09/25/2003 ENGINEERING - FINAL DROBERTS Approved
09/26/2003 ELECTRIC - TEMPORARY POLE JORTA Approved SENT TO TEP ON 0926AM
09/29/2003 RIGHT OF WAY - FINAL DLEE Approved
09/29/2003 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
09/30/2003 OUTDOOR LIGHTING FINAL JORTA Approved
09/30/2003 ELECTRIC - FINAL JORTA Approved IVRS - Inspection 0000*/ 1) SHELL FINAL
09/30/2003 ELECTRIC - TEMPORARY SERVICE JORTA Approved
10/01/2003 PERMIT FINALED JEGAN Approved
10/01/2003 FIRE - FINAL JEGAN Approved IVRS - Inspection 0000*
10/01/2003 FIRE SPKLR - FINAL JEGAN Approved IVRS - Inspection 0000*/ 1) OK FOR C OF O
10/01/2003 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*/ SHELL ONLY - NO T.I.'S INCLUDED.
10/14/2003 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection 0000*/ ALL CORRECTIONS HAVE BEEN MADE.
10/14/2003 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000* NEED PLUMBING FINAL & LETTER ACKNOWLEDGING TRANSFERENCE OF WORK FROM SHELL PERMIT TO TI PERMIT IN SPACE #150
10/15/2003 PLUMBING - FINAL RRICH Approved IVRS - Inspection 0000*/ ALL CORRECTIONS MADE.

Documents

File Name Document Type  
CALCULATIONS.TIF DOCUMENTS VIEW
TRUSSDRAWINGS.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW