Permit: T02CM05549
Permit Details
Apply Date:
12/03/2002
Applicant:
CHERYL HALL
Description:
NEW:MULTIPURPOSE ROOM
Contractors:
- ARIZONA SCHOOL FACILITIES BOARD*T
- PACIFIC BUILDING INTERIORS INC ,
Permit Reviews
Permit Number - T02CM05549
Permit Status: C of o
Permit Description: NEW:MULTIPURPOSE ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/12/2005 | REVISION | 01/12/2005 | COMPLETED |
| 04/10/2003 | RESUBMITTAL | 05/07/2003 | COMPLETED |
| 06/06/2003 | RESUBMITTAL | 06/25/2003 | COMPLETED |
| 06/30/2003 | RESUBMITTAL | 08/15/2003 | COMPLETED |
| 08/15/2003 | RESUBMITTAL | 08/15/2003 | COMPLETED |
| 12/03/2002 | COMMERCIAL TI | 03/27/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM05549
Permit Status: C of o
Permit Description: NEW:MULTIPURPOSE ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/03/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM05549
Permit Description: NEW:MULTIPURPOSE ROOM
Total Completed Inspections - 39
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2004 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection 0000*/ WASTE AND VENT TO 2' ABOVE FINISHED GRADE WTR TEST APPROVED. BLD SEWER WILL REQUIRE 4" FULL SIZE UPPER TERMINAL C.O. |
| 03/26/2004 | MECHANICAL - PROGRESS | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 03/26/2004 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/29/2004 | BUILDING - PROGRESS | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/30/2004 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
| 03/30/2004 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection :* |
| 03/30/2004 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
| 04/02/2004 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection 0000*/ WTR TEST FROM BLD ALL BLD SEWER PIPING INTO EXISTING MANHOLE PARTIAL APPROVAL PENDING CITY APPROVED DRAWING OF INSTALLATION, CERTIFICATION OF GRADE AND VIEWING OF MANHOLE BASE INVERT. |
| 04/06/2004 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection 0000*/ 2" FROM METER PVC SCH 40 TRANSITION TO 2" COPPER THRU BACKFLOW DEVISE TRANSITION TO 2" PVC SCH 40 TO BLD 70 PSI AIR TEST OK PENDING CITY APPROVED PLAN SHOWING RED LINE INSTALLATION. |
| 04/06/2004 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection 0000* |
| 06/24/2004 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection :* |
| 07/07/2004 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :*/ 1) WATER TEST THRU ROOF ON TOILET 101 + EDF OK |
| 07/07/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 07/13/2004 | PLUMBING - ROOF DRAINS | RRICH | Approved | IVRS - Inspection :* |
| 07/19/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :*/ 1) CORRECTIONS MADE 15 PSI AIR TEST FROM METER LOCATION TO (6) ROOF TOP UNITS PER APPROVED PLAN OK. CLOSET FLANGES OK |
| 07/19/2004 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/07/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :*/1)PLEASE READ ALL NOTES AND PROVIDE ALL ITEMS LISTED ON INSPECTION SHEET 2)CALL IN ALL INSPECTIONS THAT HAVE NOT BEEN APPROVED FOR BLUMBING ON YOUR PERMIT CARD 3)NORTH CENTER AIR HANDLER REQUIRES AGA OR CSA APPROVED GAS VALVE. 4)ALL SEWER CLEANOUTS TO BE TO FINISH GRADE WITH CORRECT COVERS |
| 12/07/2004 | ENGINEERING - FINAL | JSALINE | Approved | C OF O APPROVED. |
| 12/07/2004 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 12/07/2004 | SIGN - FINAL | JSONKIN | Approved | |
| 12/08/2004 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection :* |
| 12/10/2004 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* 1) BOND WATER AND GAS PIPING-CALL IN FINAL |
| 12/10/2004 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 12/10/2004 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 12/13/2004 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :*/MANHOLE IS OK |
| 12/13/2004 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 01/18/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 01/26/2005 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 01/26/2005 | MECHANICAL - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 01/26/2005 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 01/26/2005 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 01/27/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* OK FOR C OF O |
| 02/03/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 02/03/2005 | FIRE - ALARM FINAL | LTHOMAS | Approved | |
| 02/03/2005 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 02/11/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | |
| 02/11/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 02/11/2005 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection :* |
| 02/17/2005 | PERMIT FINALED | STURNEY | Approved |