Start Date Submittal Complete Date Status  
11/22/2002 RESIDENTIAL BLDG/ZONING/FLOOD 11/26/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM05423
Permit Status: C of o
Permit Description: SFR:TD#15-21-91
Total Outstanding Activity Conditions - 1
Date Name
11/22/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM05423
Permit Description: SFR:TD#15-21-91
Total Completed Inspections - 23
Date Description Inspector Results Comments
12/05/2002 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*
12/05/2002 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*
12/05/2002 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*
12/10/2002 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection 0000*
12/10/2002 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*
12/10/2002 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection 0000*
12/31/2002 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
12/31/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*/ 1) NAIL OFF DRAG STRUTS MARKED ON ROOF DECK 2) STRUCTURE ISN'T BRACES (IT'S VERY SHAKEY) 3) NEED WIND BRACING AT FRONT WALL 2ND FLOOR 4) ALL WIND BRACES TO HAVE 2 16D'S AT PLATES 5) INSTALL 2ND FLOOR H.D. DETAIL EACH END OF WALL 18-10-16/SD4 6) NAIL PANEL TO FLOOR AND NAIL SIDES OF PANELS AND BOTTOMS TO SHEAR TOP PLATE 7) NAIL SHED ROOF FRONT LEDGER MARKED IN BLACK 8) INSTALL PLYWOOD AT ENTRY, CLOSURE WALL 9) NAIL TRUSS BOTTOM CHORD TO WALL AT 93/SD-3 10) LATERAL TRUSS BRACES AT HVAC 12) NAIL SHEAR ABOVE SNUB NOSE TRUSSES, SHEAR ABOVE CEILING TO BOTTOM CHORD
01/03/2003 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection 0000*
01/03/2003 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection 0000*
01/15/2003 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
01/15/2003 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
01/16/2003 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
01/16/2003 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
01/16/2003 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*
01/16/2003 FRAMING RFREIDIN Approved IVRS - Inspection 0000*/ 1) RE-INSPECTION
01/28/2003 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*/ 1) OK 2ND STOP
03/17/2003 PERMIT FINALED HPEDROZA Approved
03/17/2003 MECHANICAL - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/17/2003 PLUMBING - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/17/2003 ELECTRIC - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/17/2003 BUILDING - FINAL HPEDROZA Approved IVRS - Inspection 0000*
03/17/2003 U VALUE FOR WINDOW HPEDROZA Approved