Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05423
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/16/2003 | FRAMING | Approved | IVRS - Inspection 0000*/ 1) RE-INSPECTION | |
01/15/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) MASTER BEDROOM EAST WALL, G4 DRYWALL, IS BLOCKED WALL, ADD BLOCKS 4' 2) MISSED A.B. AT BOTTOM PLATE SPLICES 2 PLACES 3) NAIL BLOCKS TO DOUBLE TOP PLATE TIGHT FIT ADD SPACERS 6/SD3 4) CHECK FOR NAILING ASK CARPENTER 93/SD3 5) BROKEN TRUSS MARKED ON FLOOR 2ND FLOOR AT HVAC EQUIPMENT 6) TAPE ON ROMEX LIVING ROOM MAKRED ON FLOOR 7) MOVE FT. VENT, IT'S OUT OF WALL 8) INSTALL ALL BANG PLATES 9) MOVE PEX AT CAN LIGTH, CANTILIVER LIVING ROOM 10) NEED WATER TEST DWV |