Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
11/12/2002
Applicant:
MONTEREY HOMES CONSTRUCTION INC *C
Description:
SFR:TD#15-21-91
Contractors:
  • MONTEREY HOMES CONSTRUCTION INC *C

Permit Reviews

Permit Number - T02CM05241
Permit Status: C of o
Permit Description: SFR:TD#15-21-91
Start Date Submittal Complete Date Status  
11/12/2002 RESIDENTIAL BLDG/ZONING/FLOOD 11/14/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM05241
Permit Status: C of o
Permit Description: SFR:TD#15-21-91
Total Outstanding Activity Conditions - 1
Date Name
11/12/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM05241
Permit Description: SFR:TD#15-21-91
Total Completed Inspections - 24
Date Description Inspector Results Comments
11/18/2002 PLUMBING - SEWER HCS CONNECT BSTEVENS Approved IVRS - Inspection 0000*
11/18/2002 PLUMBING - YARD WTR LINE/TEST BSTEVENS Approved IVRS - Inspection 0000*
11/18/2002 PLUMBING - ROUGH, SOIL BSTEVENS Approved IVRS - Inspection 0000*
11/21/2002 ELECTRIC - UFER DQUINN Approved IVRS - Inspection 0000*
11/21/2002 BUILDING PRE-SLAB DQUINN Approved IVRS - Inspection 0000*
11/21/2002 EXCAVATION/LAYOUT REBAR & ZON DQUINN Approved IVRS - Inspection 0000*
12/13/2002 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
12/13/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*/ 1) G ON CENTER NAILING OSB BAND FLOOR=TO=FLOOR 2) VERTICAL AT INTERMEDIATE GLU LAM BRING SAME # OF STUDS DOWN TO AND IN BETWEEN FLOOR JOISTS, WILL CHECK AT INTERMEDIATES
12/13/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*/ 1) NEED SAME VERTICAL ST FOR CONCENTRATED LOADS GLU LAMS FROM ROOF TO FLOOR 2) ADD 2 X 6 STRONG BACK IN FLOOR JOISTS PER TRUSS CALC'S 3) ADD 2 16D'S AT TOP BOTTOM PLATES WIND BRACES 4) PLYWOOD BAND FOR LATERAL AT FLAT FLOOR TRUSSES 1ST TO 2ND FLOOR EAST WEST
12/18/2002 ELECTRIC - TEMPORARY SERVICE FGREER Approved IVRS - Inspection 0000*
12/18/2002 ELECTRIC - CABLE DROP FGREER Approved IVRS - Inspection 0000*
12/31/2002 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/31/2002 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
12/31/2002 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/31/2002 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/31/2002 FRAMING RFREIDIN Approved IVRS - Inspection 0000*
01/17/2003 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*
03/24/2003 PERMIT FINALED RFREIDIN Approved
03/24/2003 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/24/2003 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/24/2003 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/24/2003 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/24/2003 U VALUE FOR WINDOW RFREIDIN Approved
03/24/2003 STUCCO MESH RFREIDIN Approved