Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM05241
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NEED SAME VERTICAL ST FOR CONCENTRATED LOADS GLU LAMS FROM ROOF TO FLOOR 2) ADD 2 X 6 STRONG BACK IN FLOOR JOISTS PER TRUSS CALC'S 3) ADD 2 16D'S AT TOP BOTTOM PLATES WIND BRACES 4) PLYWOOD BAND FOR LATERAL AT FLAT FLOOR TRUSSES 1ST TO 2ND FLOOR EAST WEST | |
12/13/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000*/ 1) G ON CENTER NAILING OSB BAND FLOOR=TO=FLOOR 2) VERTICAL AT INTERMEDIATE GLU LAM BRING SAME # OF STUDS DOWN TO AND IN BETWEEN FLOOR JOISTS, WILL CHECK AT INTERMEDIATES |