Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05241
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/09/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/08/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) 93/SD3 BLOCKS AND TRUSSES TO BE NAILED TO WALL 2) LINE SETS OUT OF WALL 1ST FLOOR 3) BANG PLATES 1ST FLOOR TOILET WATER, POWDER ROOM CEILING 4) NAIL ALL SHEAR TRANSFER BLOCKS WHEN ROOF LOADED 5) REPAIR ALL DAMAGE FROM DRY WALL LOADERS 6) MOVE VENT 1ST FLOOR SHOWER DIVERTER STUD | |
01/06/2003 | FRAMING | Denied | 1) NAIL BLOCKS TO BEAM AND BEARING WALL PER 93/SD3 2) LOAD ROOF THEN NAIL LADDER BLOCKING TO SHEARWALL TRANSFERS. NAIL SHEAR PANEL BLOCKS TO FLOOR DECK PER DT6, SD2 3) NEED FULL SUPPORT FROM GLU LAM FLOOR VERTICALLY, NAIL ALL VERTICAL STUDS TOGETHER 4) BLOCKING PANELS DETAIL 1A OF SD2 NAIL TO FLOOR DECK 8D'S AT 6" ON CENTER 5) NEED WIND BRACE ON FRONT WALL OF 2ND FLOOR 6) PROVIDE SUPPORTS FOR FURNACE 7) SHEARWALL 2ND FLOOR G3 BETWEEN BEDROOM AND BONUS ROOM A, ATTACHE EACH END OF WALL BOTTOM PLATE PER DETAIL 16, 18 AND 21 OF SD4 8) BANG PLATE ON 1ST FLOOR WATER CLOSET SUPPLY LINE 9) SHOWER DIVERTER STUD NOTCHED TO DEEP 10) NEED 60 DEGREE ON WATER HEATER VENT PIPE 11) STRAP ACCROSS TUB VENT PLATE 12) NEED ANCHOR BOLT AT SILL PLATE SPICE ON EAST WALL OF GARAGE 13) GARAGE SHEARWALL NAIL PANEL BOTTOM PLATE TO DOUBLE TOP PLATE WITH 5-16D'S PER PANEL. PER 6/SD2 14) UPSTAIRS BATH NEED ADDITIONAL SUPPORT FOR DIVERTER VALVE | |
01/03/2003 | FRAMING | Denied | IVRS - Inspection 0999* 1) PROVIDE NAIL PROTECTION @ CHASE 2ND FLOOR 2) LEAK @ TUB DRAIN 3) PROVIDE CLARIFICATION FOR 17 SD2 4) TRUSS BRQ DETAIL 93 NOT PER PLAN 5) CLIP TRUSSES PER PLAN SEE 14 SO3 & 93 SD3 | |
12/31/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |