Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM05241

Parcel: 141305980

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM05241

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/09/2003 FRAMING Approved IVRS - Inspection 0000*
01/08/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) 93/SD3 BLOCKS AND TRUSSES TO BE NAILED TO WALL 2) LINE SETS OUT OF WALL 1ST FLOOR 3) BANG PLATES 1ST FLOOR TOILET WATER, POWDER ROOM CEILING 4) NAIL ALL SHEAR TRANSFER BLOCKS WHEN ROOF LOADED 5) REPAIR ALL DAMAGE FROM DRY WALL LOADERS 6) MOVE VENT 1ST FLOOR SHOWER DIVERTER STUD
01/06/2003 FRAMING Denied 1) NAIL BLOCKS TO BEAM AND BEARING WALL PER 93/SD3 2) LOAD ROOF THEN NAIL LADDER BLOCKING TO SHEARWALL TRANSFERS. NAIL SHEAR PANEL BLOCKS TO FLOOR DECK PER DT6, SD2 3) NEED FULL SUPPORT FROM GLU LAM FLOOR VERTICALLY, NAIL ALL VERTICAL STUDS TOGETHER 4) BLOCKING PANELS DETAIL 1A OF SD2 NAIL TO FLOOR DECK 8D'S AT 6" ON CENTER 5) NEED WIND BRACE ON FRONT WALL OF 2ND FLOOR 6) PROVIDE SUPPORTS FOR FURNACE 7) SHEARWALL 2ND FLOOR G3 BETWEEN BEDROOM AND BONUS ROOM A, ATTACHE EACH END OF WALL BOTTOM PLATE PER DETAIL 16, 18 AND 21 OF SD4 8) BANG PLATE ON 1ST FLOOR WATER CLOSET SUPPLY LINE 9) SHOWER DIVERTER STUD NOTCHED TO DEEP 10) NEED 60 DEGREE ON WATER HEATER VENT PIPE 11) STRAP ACCROSS TUB VENT PLATE 12) NEED ANCHOR BOLT AT SILL PLATE SPICE ON EAST WALL OF GARAGE 13) GARAGE SHEARWALL NAIL PANEL BOTTOM PLATE TO DOUBLE TOP PLATE WITH 5-16D'S PER PANEL. PER 6/SD2 14) UPSTAIRS BATH NEED ADDITIONAL SUPPORT FOR DIVERTER VALVE
01/03/2003 FRAMING Denied IVRS - Inspection 0999* 1) PROVIDE NAIL PROTECTION @ CHASE 2ND FLOOR 2) LEAK @ TUB DRAIN 3) PROVIDE CLARIFICATION FOR 17 SD2 4) TRUSS BRQ DETAIL 93 NOT PER PLAN 5) CLIP TRUSSES PER PLAN SEE 14 SO3 & 93 SD3
12/31/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*