Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
10/22/2002
Applicant:
METRO PERMIT EXPRESS, INC
Description:
TI:OFFICE
Architects:
  • SAYLER-BROWN, THOMAS
Contractors:
  • CEDARLAKE COMPANY OF OREGON

Permit Reviews

Permit Number - T02CM04898
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
10/22/2002 COMMERCIAL TI 10/28/2002 COMPLETED Review Details
12/20/2002 REVISION 12/20/2002 COMPLETED Review Details
12/27/2002 REVISION 12/27/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM04898
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
10/22/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM04898
Permit Description: TI:OFFICE
Total Completed Inspections - 20
Date Description Inspector Results Comments
11/26/2002 PLUMBING - INTERMEDIATE FMCCLURE Approved OK TO COVER WALLS & FLOORS CALL FOR CLOSET RING INSPECTION.
11/26/2002 PLUMBING - ROUGH, SOIL FMCCLURE Approved
11/26/2002 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection 0999*I NEED TO SEE FRONT AREA COMPLETED OK TO COVER 101,105 AND BATHROOMS WHEN PLUMBING & ELECTRIC APPROVED.
11/26/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*REVISE PLAN FOR AS BUILT. I.E. RELOCATION OF LAV, TOILET AND DOOR IN HC BATHROOM
2.) FRAMING IS 2 X 4 WOOD AS OPPOSED TO STEEL STUDS INDICATED ON PLAN. FIRE BLOCKING IS OK OK TO COVER.
12/02/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved
12/02/2002 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection 0000*
Check your exit and cieling mounted fixtures to be sure if you will need a "J" box for wire junction or not.
12/05/2002 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
1.) SHEETROCK NAILING MEETS IBC REQS.
2.) NO PLAN ON SITE TO CHECK IF THERE ARE ANY EXTRA REQUIREMENTS.
3.) OK TO TAPE ASSUMING STANDARD GYP BOARD AND NAILING IS WHAT PLAN REQUIRES.
12/23/2002 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*
12/23/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*1.) COMMERICAL WATER CLOSETS TO BE ELONGATED BOWL W/ OPEN FRONT SET
2.) HANDICAPPED WATER CLOSET TO HAVE FLUSH HANDLE ON WIDE SIDE OF OPENING FRONT
3.) CAULK ALL FIXTURES
4.) NO GAS ON THIS PROJECT.
5.) NEED TO SEE CLOSET FLANGE AT HC/WC
6.) SECURE PERMIT FOR NEW WATER HEATER
7.) ALL HOSE BIBBS REQUIRE VACUUM BREAKERS
8.) NO CLEAN OUT BEHIND H.C. WATER CLOSET.
12/23/2002 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection 0000*
12/23/2002 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
12/23/2002 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection 0000*
12/23/2002 ELECTRIC - FINAL MCAPISTR Approved IVRS - Inspection 0000*
12/23/2002 ELECTRIC - ABOVE CEILING MCAPISTR Approved
12/31/2002 BUILDING - FINAL RSUBA Approved IVRS - Inspection 0999*LOCKED TO BE ABLE TO SEE FROM THE STREET (BROADWAY) NOT JUST WEST OF BUILDING.
01/07/2003 SIGN - FINAL DJOHNSTO Approved IVRS - Inspection 0000*
01/07/2003 ENGINEERING - FINAL JBRUCKME Approved
01/07/2003 FIRE - FINAL JEGAN Approved IVRS - Inspection 0000*OKAY FOR C OF O.
01/08/2003 PERMIT FINALED CWILLIAM Approved
01/08/2003 RIGHT OF WAY - FINAL LLOPEZ Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
None CERT OF OCC VIEW