Permit: T02CM04898

Parcel: 129020890


Addresses:

2526 E BROADWAY BL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/06/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
01/02/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*
CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. REPAIR HOLE IN VENT.
MARK UNIT DATA PLATE W/PROPER HEAT KIT INSTALLED & FUSE UNIT ACCORDINGLY PROVIDE MIN. 1/8" PER FT SLOPE ON CONDENSATE DRAIN. RECALL FOR INSPECTION.
12/23/2002 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection 0000*