Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM04898

Parcel: 129020890


Addresses:

2526 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02CM04898

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/03/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
1.) USE APPROVED 3" COUNTER SUNK TAPPED CLEAN OUT PLUG.
2.) INSTALL DUTCHMAN ON CLOSET RING. PIPING TO BE EVEN WITH THE TOP OF THE FLANGE.
REINSPECTED 1;45 PM
1.) CLOSET FLANGE OK OK TO RE-SET WATER CLOSET
2.) APPROVED PLUG AT CLEANOUT OK
3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS.
01/02/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.
12/23/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) COMMERICAL WATER CLOSETS TO BE ELONGATED BOWL W/ OPEN FRONT SET
2.) HANDICAPPED WATER CLOSET TO HAVE FLUSH HANDLE ON WIDE SIDE OF OPENING FRONT
3.) CAULK ALL FIXTURES
4.) NO GAS ON THIS PROJECT.
5.) NEED TO SEE CLOSET FLANGE AT HC/WC
6.) SECURE PERMIT FOR NEW WATER HEATER
7.) ALL HOSE BIBBS REQUIRE VACUUM BREAKERS
8.) NO CLEAN OUT BEHIND H.C. WATER CLOSET.