Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02CM04898
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/03/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* 1.) USE APPROVED 3" COUNTER SUNK TAPPED CLEAN OUT PLUG. 2.) INSTALL DUTCHMAN ON CLOSET RING. PIPING TO BE EVEN WITH THE TOP OF THE FLANGE. REINSPECTED 1;45 PM 1.) CLOSET FLANGE OK OK TO RE-SET WATER CLOSET 2.) APPROVED PLUG AT CLEANOUT OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
|
01/02/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. | |
12/23/2002 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*1.) COMMERICAL WATER CLOSETS TO BE ELONGATED BOWL W/ OPEN FRONT SET 2.) HANDICAPPED WATER CLOSET TO HAVE FLUSH HANDLE ON WIDE SIDE OF OPENING FRONT 3.) CAULK ALL FIXTURES 4.) NO GAS ON THIS PROJECT. 5.) NEED TO SEE CLOSET FLANGE AT HC/WC 6.) SECURE PERMIT FOR NEW WATER HEATER 7.) ALL HOSE BIBBS REQUIRE VACUUM BREAKERS 8.) NO CLEAN OUT BEHIND H.C. WATER CLOSET. |